Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests

被引:46
作者
Kettenbach, J
Kronreif, G
Figl, M
Birkfellner, W
Hanel, R
Bergmann, H
机构
[1] Med Univ Vienna, Gen Hosp, Dept Radiol, Div Angiog & Intervent Radiol, A-1090 Vienna, Austria
[2] ARC Seibersdorf Res, Robot Lab, A-2444 Seibersdorf, Austria
[3] Med Univ Vienna, Gen Hosp, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
关键词
biopsies; interventional procedures; ultrasound;
D O I
10.1007/s00330-004-2487-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to develop a robotic system for ultrasound (US)-guided biopsy and to validate the feasibility, accuracy and efficacy using phantom tests. Twenty peas (mean diameter 9.3 +/- 0.1 mm) embedded within a gel-phantom were selected for biopsy. Once the best access was defined, the position of the US transducer was recorded by an optical tracking system. Positional data of the transducer and the corresponding US image were transferred to the roboter planning system (LINUX-based industrial PC equipped with video capture card). Once the appropriate position, angulation and pitch were calculated, the robotic arm moved automatically with seven degrees-of-freedom to the planned insertion path, aiming the needle-positioning unit at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured, and the deviation of the actual needle tract from the center of the target was evaluated sonographically. In all targets, the biopsy specimen (mean length 5 +/- 1.2 mm) was harvested with only one needle pass required The mean deviation of the needle tip from the center of the target was 1.1 +/- 0.8 mm. Robotic assisted biopsies in-vitro using US-guidance were feasible and provided high accuracy.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 23 条
[1]   A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences [J].
Bale, RJ ;
Lottersberger, C ;
Vogele, M ;
Prassl, A ;
Czermak, B ;
Dessl, A ;
Sweeney, RA ;
Waldenberger, P ;
Jaschke, W .
EUROPEAN RADIOLOGY, 2002, 12 (12) :2890-2894
[2]  
Benabid AL, 1995, B CANCER, V82, pS573
[3]   ROBODOC -: A way to the future in hip endoprosthesis or a unnecessary investment? [J].
Birke, A ;
Reichel, H ;
Hein, W ;
Schietsch, U ;
Hube, R ;
Bernstein, A ;
Krüger, T .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05) :395-401
[4]   First experiences with the da Vinci™ operating robot in thoracic surgery [J].
Bodner, J ;
Wykypiel, H ;
Wetscher, G ;
Schmid, T .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (05) :844-851
[5]  
Cleary K, 2001, Comput Aided Surg, V6, P312, DOI 10.3109/10929080109146301
[6]  
Clifford Mark A, 2002, Comput Aided Surg, V7, P291, DOI 10.1002/igs.10049
[7]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[8]   System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance [J].
Fichtinger, G ;
DeWeese, TL ;
Patriciu, A ;
Tanacs, A ;
Mazilu, D ;
Anderson, JH ;
Masamune, K ;
Taylor, RH ;
Stoianovici, D .
ACADEMIC RADIOLOGY, 2002, 9 (01) :60-74
[9]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[10]   Stereotactic and ultrasound-guided breast biopsy [J].
Helbich T.H. ;
Matzek W. ;
Fuchsjäger M.H. .
European Radiology, 2004, 14 (3) :383-393