Nanoliter serum sample analysis by mid-infrared spectroscopy for minimally invasive blood-glucose monitoring

被引:37
作者
Diessel, E [1 ]
Kamphaus, P
Grothe, K
Kurte, R
Damm, U
Heise, HM
机构
[1] Bayer Technol Serv, Biophys Competence Ctr, D-51368 Leverkusen, Germany
[2] Univ Dortmund, Inst Analyt Sci, ISAS, D-44139 Dortmund, Germany
关键词
infrared spectroscopy; attenuated total reflection; ATR; glucose; micro-dispenser; dry film sample preparation;
D O I
10.1366/0003702053641360
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to demonstrate that mid-infrared spectroscopy is able to quantify glucose in a serum matrix with sample volumes well below 1 mu L. For this, we applied mid-infrared attenuated total reflectance (ATR) or transmission-based spectroscopic methods to glucose quantification in microsamples of dry-film sera, either undiluted or diluted 10 times in distilled water. The sample series spanned physiological glucose concentrations between 50 and 600 mg/dL and volumes of 80, 8, and 1 nL. Calibration was carried out using multivariate partial least-squares (PLS) modeling with spectral data between 1180 and 940 cm(-1). Best performance was achieved in the ATR experiments. For raw ATR spectra, the optimum standard error of prediction (SEP) of 13.3 mg/dL was obtained for the 8 nL sample series with subsequent 10-fold dilution. With respect to the coefficient of variation of the glucose assay, CVpred, we obtained a value of 3 % for the 80 nL volume samples with spectral preprocessing using matrix protein absorption bands as an internal standard, 4 % for the 8 nL samples, and 6 % for the I nL samples with raw data. Spectral standardization resulted in significant improvement, especially for the 80 nL volume sample series. By contrast, the accuracy of the glucose assay for the I nL sample volume series could not be improved either by internal standardization or by considering the dry film areas for normalization, which we attribute to varying topographies of the dry films.
引用
收藏
页码:442 / 451
页数:10
相关论文
共 30 条
[1]   Dry film preparation from whole blood, plasma and serum for quantitative infrared diffuse reflectance spectroscopy [J].
Bittner, A ;
Heise, HM .
FOURIER TRANSFORM SPECTROSCOPY, 1998, (430) :278-281
[2]  
BOESE M, 2004, Patent No. 20040113072
[3]  
BOLSHOV MA, 2002, SPECTROCHIM ACTA B, V57, P1547
[4]   Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum [J].
Budinova, G ;
Salva, J ;
Volka, K .
APPLIED SPECTROSCOPY, 1997, 51 (05) :631-635
[5]  
Collison ME, 1999, CLIN CHEM, V45, P1665
[6]   Applications of FT-IR spectrometry to plasma contents analysis and monitoring [J].
Déléris, G ;
Petibois, C .
VIBRATIONAL SPECTROSCOPY, 2003, 32 (01) :129-136
[7]   Glucose quantification in dried-down nanoliter samples using mid-infrared attenuated total reflection spectroscopy [J].
Diessel, E ;
Willmann, S ;
Kamphaus, P ;
Kurte, R ;
Damm, U ;
Heise, HM .
APPLIED SPECTROSCOPY, 2004, 58 (04) :442-450
[8]   Blood analysis by Raman spectroscopy [J].
Enejder, AMK ;
Koo, TW ;
Oh, J ;
Hunter, M ;
Sasic, S ;
Feld, MS ;
Horowitz, GL .
OPTICS LETTERS, 2002, 27 (22) :2004-2006
[9]   Flow-through picoliter dispenser: A new approach for solvent elimination in FT-IR spectroscopy [J].
Haberkorn, M ;
Frank, J ;
Harasek, M ;
Nilsson, J ;
Laurell, T ;
Lendl, B .
APPLIED SPECTROSCOPY, 2002, 56 (07) :902-908
[10]  
Heise H. M., 2005, ENCY ANAL SCI, V2, P152