Self-supporting uncooled infrared microbolometers with low-thermal mass

被引:65
作者
Almasri, M [1 ]
Butler, DP [1 ]
Çelik-Butler, Z [1 ]
机构
[1] So Methodist Univ, Dallas, TX 75275 USA
基金
美国国家航空航天局; 美国国家科学基金会;
关键词
microbolometers; micromachining; uncooled infrared detection; yttrium barium copper oxide;
D O I
10.1109/84.946808
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new micromachined microbolometer array structure is presented that utilizes a self-supporting semiconducting yttrium barium copper oxide (Y-Ba-Cu-O) thin film thermometer. The Y-Ba-Cu-O thermometer is held above the substrate only by the electrode arms without the need of any underlying supporting membrane. This represents a significant improvement in the state-of-the-art for microbolometers by eliminating the thermal mass associated with the supporting membrane. The reduced thermal mass permits lowering the thermal conductance to the substrate to obtain increased responsivity or having a shorter thermal time constant to allow for higher frame rate camera. The simple structure does not suffer from warping problems associated with stress imbalances in multilayer microbolometer structures that utilize a supporting membrane such as Si3N4. Devices were fabricated by growing Y-Ba-Cu-O films on a conventional polyimide sacrificial layer mesa. Subsequent etching of the sacrificial layer provides the air gap that thermally isolates the microbolometer. Y-Ba-Cu-O possesses a relatively high temperature coefficient of resistance of 3.1%/K at room temperature. The 400-mn-thick Y-Ba-Cu-O film exhibited absorptivity of about 30%. The responsivity and detectivity approached 10(4) V/W and 10(8) cm Hz(1/2)/W to filtered blackbody infrared (IR) radiation covering the 2.5 to 13.5 mum band. This extrapolates to noise equivalent temperature difference (NETD) less than 100 mK. The micromachining techniques employed are post-complementary metal-oxide-semiconductor (CMOS) compatible, allowing for the fabrication of focal plane arrays for IR cameras.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 35 条
  • [1] Free standing amorphous Y-Ba-Cu-O detectors for uncooled IR detection and the effects of doping
    Almasri, M
    Butler, DP
    Celik-Butler, Z
    [J]. MATERIALS AND ELECTRONICS FOR HIGH-SPEED AND INFRARED DETECTORS, 1999, 3794 : 66 - 75
  • [2] ALMASRI M, 2001, P SPIE AER INFR TECH, V27
  • [3] ALMASRI M, 2000, SPIE, V4028, P17
  • [4] Uncooled monolithic ferroelectric IRFPA technology
    Belcher, JF
    Hanson, CM
    Beratan, HR
    Udayakumar, KR
    Soch, KL
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 611 - 622
  • [5] BOARINO L, 1998, P 4 THERMINIC WORKSH
  • [6] HIGH T-C SUPERCONDUCTOR BOLOMETER WITH RECORD PERFORMANCE
    BRASUNAS, JC
    LAKEW, B
    [J]. APPLIED PHYSICS LETTERS, 1994, 64 (06) : 777 - 778
  • [7] More applications of uncooled microbolometer sensors
    Breen, T
    Butler, N
    Kohin, M
    Marshall, CA
    Murphy, R
    Parker, T
    Silva, R
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 530 - 540
  • [8] Micromachined YBaCuO capacitor structures as uncooled pyroelectric infrared detectors
    Butler, DP
    Celik-Butler, Z
    Jahanzeb, A
    Gray, JE
    Travers, CM
    [J]. JOURNAL OF APPLIED PHYSICS, 1998, 84 (03) : 1680 - 1687
  • [9] Charge transport in amorphous and tetragonal semiconducting YBaCuO films
    CelikButler, Z
    Shan, PC
    Butler, DP
    Jahanzeb, A
    Travers, CM
    Kula, W
    Sobolewski, R
    [J]. SOLID-STATE ELECTRONICS, 1997, 41 (06) : 895 - 899
  • [10] CELIKBUTLER Z, 1999, WILEY ENCY ELECT ELE, V10, P198