Intravascular magnetic resonance imaging using a loopless catheter antenna

被引:188
作者
Ocali, O [1 ]
Atalar, E [1 ]
机构
[1] JOHNS HOPKINS UNIV HOSP,SCH MED,DEPT RADIOL,BALTIMORE,MD 21287
关键词
intravascular MRI; MR catheter coil; atherosclerosis; MRI of arterial wall;
D O I
10.1002/mrm.1910370116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, intravascular catheter probes have been developed to increase signal-to-noise ratio (SNR) for MR imaging of blood vessels. Miniaturization of these catheter probes without degrading their performances is very critical in imaging small vessels such as coronary arteries. Catheter coils have a loop incorporated in their structure and have limitations in physical dimensions and electromagnetic properties. The use of a loopless intravascular catheter antenna is proposed to overcome these problems. The catheter antenna is essentially a dipole, which makes a very thin diameter possible, and its electronic circuitry can be placed outside the blood vessels without performance degradation. The theoretical foundation for the design and operation of the catheter antenna is presented. Several catheter antennae, as small as 1.5 French, were constructed and tested on phantoms and rabbits with great success. The catheter antenna has a simple structure and is easy to design, implement, and operate.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 17 条
[1]   EVALUATION OF ATHEROSCLEROTIC LESIONS USING NMR MICROIMAGING [J].
ASDENTE, M ;
PAVESI, L ;
ORESTE, PL ;
COLOMBO, A ;
KUHN, W ;
TREMOLI, E .
ATHEROSCLEROSIS, 1990, 80 (03) :243-253
[2]  
ATALAR E, P SMR 3 ANN M NIC 19, P988
[3]  
Chiabrera A., 1985, Interactions between Electromagnetic Fields and Cells, DOI DOI 10.1016/C2013-0-02552-2
[4]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[5]   INTRAVASCULAR (CATHETER) NMR RECEIVER PROBE - PRELIMINARY DESIGN ANALYSIS AND APPLICATION TO CANINE ILIOFEMORAL IMAGING [J].
HURST, GC ;
HUA, JM ;
DUERK, JL ;
COHEN, AM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) :343-357
[6]  
Kandarpa K, 1993, J Vasc Interv Radiol, V4, P419, DOI 10.1016/S1051-0443(93)71891-6
[7]   INVIVO P-31 NUCLEAR MAGNETIC-RESONANCE MEASUREMENTS IN CANINE HEART USING A CATHETER-COIL [J].
KANTOR, HL ;
BRIGGS, RW ;
BALABAN, RS .
CIRCULATION RESEARCH, 1984, 55 (02) :261-266
[8]   INTRAVASCULAR MR-IMAGING IN A PORCINE ANIMAL-MODEL [J].
MARTIN, AJ ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) :224-229
[9]   MR IMAGING OF BLOOD-VESSELS WITH AN INTRAVASCULAR COIL [J].
MARTIN, AJ ;
PLEWES, DB ;
HENKELMAN, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04) :421-429
[10]  
MCDONALD GG, 1993, RADIOLOGY P, V189, P319