Insertion devices for BESSY II

被引:5
作者
Bahrdt, J [1 ]
Gaupp, A [1 ]
Ingold, G [1 ]
Scheer, M [1 ]
Gudat, W [1 ]
机构
[1] BESSYMBH, D-14195 Berlin, Germany
关键词
insertion devices; phase errors;
D O I
10.1107/S0909049597013757
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high-brilliance synchrotron radiation source BESSY II will provide space for the installation of 14 insertion devices. At the time of writing (July 1997), eight insertion devices are funded. The first light for use by scientists will be available in January 1999. The undulators are designed for a scanning operation in parallel with the monochromator. This modus requires tight tolerances concerning the drive system. The first insertion device to be installed, a U-49 undulator, has been assembled and magnetically measured. The r.m.s. phase error is 2 degrees. An endpole configuration using coils with less than 64 amp-turns makes the angular kick smaller than +/-3 mu rad over a gap range 15-50 mm.
引用
收藏
页码:443 / 444
页数:2
相关论文
共 5 条
[1]  
BACKER H, 1995, BESSY ANN REPORT, P539
[2]  
BAHRDT J, 1996, P 5 EUR PART ACC C, V3, P2535
[3]  
BAHRDT J, 1995, BESSY ANN REPORT, P542
[4]  
CHAVANNE J, 1995, P PAC95, V2, P1319
[5]   DESIGN OF A NEW-TYPE OF PLANAR UNDULATOR FOR GENERATING VARIABLY POLARIZED RADIATION [J].
SASAKI, S ;
KAKUNO, K ;
TAKADA, T ;
SHIMADA, T ;
YANAGIDA, K ;
MIYAHARA, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 331 (1-3) :763-767