The heart-Hemopump interaction: A study of Hemopump flow as a function of cardiac activity

被引:15
作者
Meyns, B [1 ]
Siess, T [1 ]
Laycock, S [1 ]
Reul, H [1 ]
Rau, G [1 ]
Flameng, W [1 ]
机构
[1] RHEIN WESTFAL TH AACHEN,HELMHOLTZ INST BIOMED ENGN,AACHEN,GERMANY
关键词
mechanical assistance; postcardiotomy heart failure; Hemopump; rotary blood pump;
D O I
10.1111/j.1525-1594.1996.tb04496.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Hemopump is a useful left ventricular assist device. Because it is a rotary blood pump, the pump performance is not constant and is dependent on the cardiac cycle. We measured the static flow delivered by the pump at varying pressure heads (Delta P) in a mock circulation. These data are compared to the pump performance in vivo. On the basis of these results, 5 sheep were instrumented for continuous Hemopump flow measure ment as well as left ventricular and aortic pressure measurements. The Hemopump flow was relayed instantaneously to the pressure head. Low filling and ventricular failing (through intravenous administration of a beta-blocker) conditions were applied. The in vivo measured flows also are pressure head dependent, but the flow curve shows hysteresis resulting in a loop during each cardiac cycle. The in vivo peak flows (Delta P = 0) are similar to the in vitro data. The in vivo means flows (a = 50 mm Hg) are similar to the in vitro data for the lower pump speeds but are less than that at the higher pump speeds (3.74 +/- 0.55 L/min in vivo at Speed 7 versus 4.6 L/min in vitro). Low filling interrupts the Delta P-flow loop and reduces flow. In the failing ventricle, Delta P increases and flow is reduced. The cannula leaks and results in aortic insufficiency (0.36 +/- 0.05 L/min) when the pump is turned off. Several conclusions have been drawn from these tests: Cardiac activity is beneficial for the pump performance as well as when the aortic pressure curve is nonpulsatile; the longer the systolic phase, the higher the pump flow; the pump should never be turned off in clinical use; and filling is important for the pump's performance.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 11 条
  • [1] AHN HC, 1995, ANN THORAC SURG, V59, pS39
  • [2] UNIVENTRICULAR AND BIVENTRICULAR THORATEC VAD SUPPORT AS A BRIDGE TO TRANSPLANTATION
    FARRAR, DJ
    HILL, JD
    [J]. ANNALS OF THORACIC SURGERY, 1993, 55 (01) : 276 - 282
  • [3] FLAMENG W, 1991, TEMPORARY CARDIAC AS, P73
  • [4] POSTCARDIOTOMY CENTRIFUGAL MECHANICAL VENTRICULAR SUPPORT
    GOLDING, LAR
    CROUCH, RD
    STEWART, RW
    NOVOA, R
    LYTLE, BW
    MCCARTHY, PM
    TAYLOR, PC
    LOOP, FD
    COSGROVE, DM
    [J]. ANNALS OF THORACIC SURGERY, 1992, 54 (06) : 1059 - 1064
  • [5] POSTCARDIOTOMY SHOCK - CLINICAL-EVALUATION OF THE BVS-5000 BIVENTRICULAR SUPPORT SYSTEM
    GUYTON, RA
    SCHONBERGER, JPAM
    EVERTS, PAM
    JETT, GK
    GRAY, LA
    GIELCHINSKY, I
    RAESS, DH
    VLAHAKES, GJ
    WOOLLEY, SR
    GANGAHAR, DM
    SOLTANZADEH, H
    PICCIONE, WJ
    VAUGHN, CC
    BOONSTRA, PW
    BUCKLEY, MJ
    [J]. ANNALS OF THORACIC SURGERY, 1993, 56 (02) : 346 - 356
  • [6] BIO-MEDICUS VENTRICULAR ASSIST DEVICE FOR SALVAGE OF CARDIAC SURGICAL PATIENTS
    KILLEN, DA
    PIEHLER, JM
    BORKON, AM
    REED, WA
    [J]. ANNALS OF THORACIC SURGERY, 1991, 52 (02) : 230 - 235
  • [7] LEFT-VENTRICULAR ASSISTANCE WITH THE TRANSTHORACIC 24F HEMOPUMP FOR RECOVERY OF THE FAILING HEART
    MEYNS, BP
    SERGEANT, PT
    DAENEN, WJ
    FLAMENG, WJ
    [J]. ANNALS OF THORACIC SURGERY, 1995, 60 (02) : 392 - 397
  • [8] PAE WE, 1992, J THORAC CARDIOV SUR, V104, P541
  • [9] PENNINGTON DG, 1994, J HEART LUNG TRANSPL, V13, P803
  • [10] TECHNICAL REQUIREMENTS AND LIMITATIONS OF MINIATURIZED AXIAL-FLOW PUMPS FOR CIRCULATORY SUPPORT
    REUL, H
    [J]. CARDIOLOGY, 1994, 84 (03) : 187 - 193