Rectal doses in intracavitary brachytherapy of gynecological malignancies: comparison of two dosimetric methods

被引:13
作者
Serkies, K
Badzio, A
Jereczek-Fossa, B
Tarnawska, Z
Nowak, R
Szewczyk, P
Jassem, J
机构
[1] Med Univ Gdansk, Dept Radiotherapy & Oncol, PL-80211 Gdansk, Poland
[2] European Inst Oncol, Dept Radiotherapy, Milan, Italy
关键词
gynecological brachytherapy; ICRU Report 38; rectal reference point; dosimetry;
D O I
10.1016/S0167-8140(00)00325-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare calculated rectal doses obtained by two dosimetric methods in intracavitary brachytherapy of gynecological malignancies Materials and methods: This analysis included 124 intracavitary applications performed in 102 patients with cervical or endometrial cancer. The pelvic dose distribution based on orthogonal intracavitary placement films was calculated with the computer planning system. In each application the rectal dose was defined in the specific rectal point determined by both the use of a wire marker inserted into the rectum (R1) and by packing the vagina with radio-opaque gauze - the method recommended by the ICRU Report 38 (R2). The comparison included R1 and R2 doses as well as the respective radiobiological equivalent doses determined by the linear-quadratic model (r1 and r2). Results: In 83% of applications the absolute value of R1 was lower than R2. The mean difference between R1 and R2 was 3.7 Gy (95% CI 3.03-4.41 Gy) and between r1 and r2 7.2 Gy (95% CI 5.77-8.56 Gy). These differences were significant (P < 0.001 for both comparisons). The difference between the doses was not influenced by the type of applicator and remained significant even when a systemic +/- 10% error of method was assumed. Conclusion: The rectal point dose determined with the use of rectal wire marker may be underestimated, therefore this method should be discouraged in gynecological brachytherapy. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 18 条
[1]   UNCERTAINTY IN DOSE ESTIMATION FOR GYNECOLOGICAL IMPLANTS [J].
CHOW, H ;
LANE, RG ;
ROSEN, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (06) :1555-1559
[2]   RECTAL COMPLICATIONS IN PATIENTS WITH CARCINOMA OF THE CERVIX TREATED WITH CONCOMITANT CISPLATIN AND EXTERNAL-BEAM IRRADIATION WITH HIGH-DOSE-RATE BRACHYTHERAPY - A DOSIMETRIC ANALYSIS [J].
CLARK, BG ;
SOUHAMI, L ;
ROMAN, TN ;
EVANS, MDC ;
PLA, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05) :1243-1250
[3]   The prediction of late rectal complications in patients treated with high dose-rate brachytherapy for carcinoma of the cervix [J].
Clark, BG ;
Souhami, L ;
Roman, TN ;
Chappell, R ;
Evans, MDC ;
Fowler, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05) :989-993
[4]   Dosimetry of intracavitary applications in carcinoma of the cervix: Rectal dose analysis [J].
Deshpande, DD ;
Shrivastav, SK ;
Pradhan, AS ;
Viswanathan, PS ;
Dinshaw, KA .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (02) :163-166
[5]   ANALYSIS OF COMPLICATIONS IN A PROSPECTIVE RANDOMIZED TRIAL COMPARING 2 BRACHYTHERAPY LOW-DOSE RATES IN CERVICAL-CARCINOMA [J].
HAIEMEDER, C ;
KRAMAR, A ;
LAMBIN, P ;
LANCAR, R ;
SCALLIET, P ;
BOUZY, J ;
GERBAULET, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05) :953-960
[6]  
International Commission on Radiation Units and Measurements, 1985, 38 ICRU
[7]   Late complications after postoperative radiotherapy in endometrial cancer: Analysis of 317 consecutive cases with application of linear-quadratic model [J].
Jereczek-Fossa, B ;
Jassem, J ;
Nowak, R ;
Badzio, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (02) :329-338
[8]   DOSIMETRY OF INTRACAVITARY PLACEMENTS FOR UTERINE AND CERVICAL-CARCINOMA - RESULTS OF ORTHOGONAL FILM, TLD, AND CT-ASSISTED TECHNIQUES [J].
KAPP, KS ;
STUECKLSCHWEIGER, GF ;
KAPP, DS ;
HACKL, AG .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (03) :137-146
[9]  
LATHINEN T, 1993, RADIOTHER ONCOL, V8, P174
[10]   CT-ASSISTED ASSESSMENT OF BLADDER AND RECTUM DOSE IN GYNECOLOGICAL IMPLANTS [J].
LING, CC ;
SCHELL, MC ;
WORKING, KR ;
JENTZSCH, K ;
HARISIADIS, L ;
CARABELL, S ;
ROGERS, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (10) :1577-1582