Multiphoton excitation spectra in biological samples

被引:84
作者
Dickinson, ME [1 ]
Simbuerger, E
Zimmermann, B
Waters, CW
Fraser, SE
机构
[1] CALTECH, Beckman Inst, Biol Imaging Ctr, Pasadena, CA 91125 USA
[2] Carl Zeiss Jena GMBH, Adv Imaging Microscopy Div, D-07745 Jena, Germany
关键词
confocal microscopy; multiphoton microscopy; fluorescent proteins; fluorescence; multicolor imaging; excitation spectra;
D O I
10.1117/1.1583734
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multiphoton microscopy is becoming a popular mode of live and fixed cell imaging. This mode of imaging offers several advantages due to the fact that fluorochrome excitation is a nonlinear event resulting in excitation only at the plane of focus. Multiphoton excitation is enhanced by the use of ultrafast lasers emitting in the near IR, offering better depth penetration coupled with efficient excitation. Because these lasers, such as titanium:sapphire lasers, offer tunable output it is possible to use them to collect multiphoton excitation spectra. We use the software-tunable Coherent Chameleon laser coupled to the Zeiss LSM 510 META NLO to acquire x-y images of biological samples at multiple excitation wavelengths, creating excitation lambda stacks. The mean intensity of pixels within the image plotted versus excitation wavelength reveals the excitation spectra. Excitation lambda stacks can be separated into individual images corresponding to the signal from different dyes using linear unmixing algorithms in much the same way that emission fingerprinting can be used to generate crosstalk free channels from emission lambda stacks using the META detector. We show how this technique can be used to eliminate autofluorescence and to produce crosstalk-free images of dyes with very close overlap in their emission spectra that cannot be separated using emission fingerprinting. Moreover, excitation fingerprinting can be performed using nondescanned detectors (NDDs), offering more flexibility for eliminating autofluorescence or crosstalk between fluorochromes when imaging deep within the sample. Thus, excitation fingerprinting complements and extends the functions offered by the META detector and emission fingerprinting. We correct biases in the laser and microscope transmission to acquire realistic multiphoton excitation spectra for fluorochromes within cells using the microscope, which enables the optimization of the excitation wavelength for single and multilabel experiments and provides a means for studying the influence of the biological environment on nonlinear excitation. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:329 / 338
页数:10
相关论文
共 20 条
  • [1] Design of organic molecules with large two-photon absorption cross sections
    Albota, M
    Beljonne, D
    Brédas, JL
    Ehrlich, JE
    Fu, JY
    Heikal, AA
    Hess, SE
    Kogej, T
    Levin, MD
    Marder, SR
    McCord-Maughon, D
    Perry, JW
    Röckel, H
    Rumi, M
    Subramaniam, C
    Webb, WW
    Wu, XL
    Xu, C
    [J]. SCIENCE, 1998, 281 (5383) : 1653 - 1656
  • [2] Two-photon fluorescence absorption and emission spectra of dyes relevant for cell imaging
    Bestvater, F
    Spiess, E
    Stobrawa, G
    Hacker, M
    Feurer, T
    Porwol, T
    Berchner-Pfannschmidt, U
    Wotzlaw, C
    Acker, H
    [J]. JOURNAL OF MICROSCOPY, 2002, 208 (02) : 108 - 115
  • [3] 2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY
    DENK, W
    STRICKLER, JH
    WEBB, WW
    [J]. SCIENCE, 1990, 248 (4951) : 73 - 76
  • [4] Photon upmanship: Why multiphoton imaging is more than a gimmick
    Denk, W
    Svoboda, K
    [J]. NEURON, 1997, 18 (03) : 351 - 357
  • [5] Multi-spectral imaging and linear unmixing add a whole new dimension to laser scanning fluorescence microscopy
    Dickinson, ME
    Bearman, G
    Tille, S
    Lansford, R
    Fraser, SE
    [J]. BIOTECHNIQUES, 2001, 31 (06) : 1272 - +
  • [6] Sensitive imaging of spectrally overlapping fluorochromes using the LSM 510 META
    Dickinson, ME
    Waters, CW
    Bearman, G
    Wolleschensky, R
    Tille, S
    Fraser, SE
    [J]. MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 123 - 136
  • [7] Characterization of one- and two-photon excitation fluorescence resonance energy transfer microscopy
    Elangovan, M
    Wallrabe, H
    Chen, Y
    Day, RN
    Barroso, M
    Periasamy, A
    [J]. METHODS, 2003, 29 (01) : 58 - 73
  • [8] Video-rate scanning two-photon excitation fluorescence microscopy and ratio imaging with cameleons
    Fan, GY
    Fujisaki, H
    Miyawaki, A
    Tsay, RK
    Tsien, RY
    Ellisman, MH
    [J]. BIOPHYSICAL JOURNAL, 1999, 76 (05) : 2412 - 2420
  • [9] Spectral imaging fluorescence microscopy
    Haraguchi, T
    Shimi, T
    Koujin, T
    Hashiguchi, N
    Hiraoka, Y
    [J]. GENES TO CELLS, 2002, 7 (09) : 881 - 887
  • [10] One-photon versus two-photon excited fluorescence resonance energy transfer of GFP fusion proteins
    LaMorte, VJ
    Krasieva, TB
    Zoumi, A
    Forman, BM
    Solier, C
    [J]. MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 73 - 78