Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load

被引:210
作者
Keyak, JH [1 ]
Falkinstein, Y [1 ]
机构
[1] Univ Calif Irvine, Ctr Med, Dept Orthopaed Surg, Orange, CA 92868 USA
关键词
finite element; femur; bone strength; computed tomography; hip fracture;
D O I
10.1016/S1350-4533(03)00081-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Hip fracture is a serious and common injury that can lead to permanent disability, pneumonia, pulmonary embolism, and death. Research to help prevent these fractures is essential. Computed tomographic (CT) scan-based finite element (FE) modeling is a tool that can predict proximal femoral fracture loads in vitro. Because this tool might be used in vivo, this study examined whether FE models generated from CT scans in situ and in vitro yield comparable predictions of proximal femoral fracture load. CT scans of the left proximal femur of two human cadavers were obtained in situ and in vitro, and three-dimensional FE models employing nonlinear mechanical properties were generated from each CT scan. The models were evaluated under single-limb stance-type loading by applying displacements incrementally to the femoral head. The FE-predicted fracture load (F-FE) was the maximum femoral head reaction force. F-FE for the in situ-derived models for the two subjects were 5.2 and 13.3% greater than for the in vitro-derived models. These results demonstrate that using CT scan data obtained in situ instead of in vitro to generate FE models can lead to substantially different predicted fracture loads. This effect must be considered when using this technology in vivo. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 20 条
[1]
HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION [J].
COOPER, C ;
CAMPION, G ;
MELTON, LJ .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) :285-289
[2]
CROSS-CALIBRATION OF LIQUID AND SOLID QCT CALIBRATION STANDARDS - CORRECTIONS TO THE UCSF NORMATIVE DATA [J].
FAULKNER, KG ;
GLUER, CC ;
GRAMPP, S ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (01) :36-42
[3]
Ford CM, 1996, J BONE MINER RES, V11, P377
[4]
PREDICTING THE COMPRESSIVE MECHANICAL-BEHAVIOR OF BONE [J].
KELLER, TS .
JOURNAL OF BIOMECHANICS, 1994, 27 (09) :1159-1168
[5]
AUTOMATED 3-DIMENSIONAL FINITE-ELEMENT MODELING OF BONE - A NEW METHOD [J].
KEYAK, JH ;
MEAGHER, JM ;
SKINNER, HB ;
MOTE, CD .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (05) :389-397
[6]
Improved prediction of proximal femoral fracture load using nonlinear finite element models [J].
Keyak, JH .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (03) :165-173
[7]
Keyak JH, 1996, J BIOMED MATER RES, V31, P373
[8]
Effect of force direction on femoral fracture load for two types of loading conditions [J].
Keyak, JH ;
Skinner, HB ;
Fleming, JA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (04) :539-544
[9]
CORRELATIONS BETWEEN ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF TRABECULAR BONE - USE OF DIFFERENT DENSITOMETRIC MEASURES [J].
KEYAK, JH ;
LEE, IY ;
SKINNER, HB .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (11) :1329-1336
[10]
Keyak JH, 1998, J BIOMECH, V31, P125, DOI 10.1016/S0021-9290(97)00123-1