Immunomagnetic separation with mediated flow injection analysis amperometric detection of viable Escherichia coli O157

被引:114
作者
Pérez, FG [1 ]
Mascini, M [1 ]
Tothill, IE [1 ]
Turner, APF [1 ]
机构
[1] Univ Florence, Dipartimento Sanita Pubbl Epidemiol & Chim Analit, Florence, Italy
关键词
D O I
10.1021/ac970715t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coupling of an immunological separation (using immunomagnetic beads) with amperometric now injection analysis detection of viable bacteria is presented. Using a solution containing Escherichia coli O157, the electrochemical response with two different mediators [potassium hexacyanoferrate(III) and 2,6-dichlorophenolindophenol] was evaluated in the FIA system. Antibody-derivatized Dynabeads were used to selectively separate E. coli O157 from a matrix The kinetics and the capacity parameters regarding the attachment of bacteria to the immunobeads were studied. The immunomagnetic separation was then used in conjunction with electrochemical detection to measure the concentration of viable bacteria. A calibration curve of colony-forming units (du) against electrochemical response was obtained. The detection limit for this rapid microbiological method was 10(5) cfu mL(-1), and the complete assay was performed in 2 h. Some advantages over ELISA methods are the direct detection of viable cells (and not total bacterial load) and the need for only one antibody (not enzyme-labeled), thus making the assay faster (only one washing step is necessary) and less expensive.
引用
收藏
页码:2380 / 2386
页数:7
相关论文
共 30 条
  • [1] *AM PUBL HLTH ASS, 1995, STAND METH EX 9215C
  • [2] [Anonymous], MMWR
  • [3] TRANSMISSION OF ESCHERICHIA-COLI O157-H7 INFECTION IN MINNESOTA CHILD DAY-CARE FACILITIES
    BELONGIA, EA
    OSTERHOLM, MT
    SOLER, JT
    AMMEND, DA
    BRAUN, JE
    MACDONALD, KL
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (07): : 883 - 888
  • [4] The isolation and detection of Escherichia coli O157 by use of immunomagnetic separation and immunoassay procedures
    Bennett, AR
    MacPhee, S
    Betts, RP
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1996, 22 (03) : 237 - 243
  • [5] DEVELOPMENT OF A FLOW-INJECTION ANALYSIS (FIA) IMMUNOSENSOR FOR THE DETECTION OF ESCHERICHIA-COLI
    BOUVRETTE, P
    LUONG, JHT
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 27 (2-3) : 129 - 137
  • [6] A SEVERE OUTBREAK OF ESCHERICHIA-COLI O157-H7 - ASSOCIATED HEMORRHAGIC COLITIS IN A NURSING-HOME
    CARTER, AO
    BORCZYK, AA
    CARLSON, JAK
    HARVEY, B
    HOCKIN, JC
    KARMALI, MA
    KRISHNAN, C
    KORN, DA
    LIOR, H
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (24) : 1496 - 1500
  • [7] A COMPARISON OF IMMUNOMAGNETIC SEPARATION AND DIRECT CULTURE FOR THE ISOLATION OF VEROCYTOTOXIN-PRODUCING ESCHERICHIA-COLI O157 FROM BOVINE FECES
    CHAPMAN, PA
    WRIGHT, DJ
    SIDDONS, CA
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1994, 40 (06) : 424 - 427
  • [8] A comparison of immunomagnetic separation, direct culture and polymerase chain reaction for the detection of verocytotoxin-producing Escherichia coli O157 in human faeces
    Cubbon, MD
    Coia, JE
    Hanson, MF
    ThomsonCarter, FM
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1996, 44 (03) : 219 - 222
  • [9] IMMUNOMAGNETIC SEPARATION OF SALMONELLA FROM FOODS AND THEIR DETECTION USING IMMUNOMAGNETIC PARTICLE (IMP)-ELISA
    CUDJOE, KS
    HAGTVEDT, T
    DAINTY, R
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 27 (01) : 11 - 25
  • [10] Dynal AS, 1996, CELL SEPARATION PROT