Spectroelectrochemical detection using thermal lens microscopy with a glass-substrate micro electrode-microchannel chip

被引:8
作者
Kim, HB
Hagino, T
Sasaki, N
Watanabe, N
Kitamori, T
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Sch Engn, Engn Res Inst, Bunkyo Ku, Tokyo 1138656, Japan
[3] Kanagawa Acad Sci & Technol, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
关键词
microband electrode; channel flow; spectroelectrochemistry; simulation;
D O I
10.1016/j.jelechem.2004.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed spectroelectrochemical detection using thermal lens microscopy (EC-TLM) with a microelectrode-microchannel chip (EMC). TLM has both high sensitive and spatial resolution comparable to fluorometry, while it can be applied to non fluorescent analytes. EMC provides an efficient electrolysis of the analyte and a controlled distribution of the redox product in the microchannel. Therefore, a combination of TLM and EMC enhance both the sensitivity and selectivity. To show the performance of EC-TLM, we fabricated a glass substrate EMC and constructed the detection system. Experiments showed that the potential dependence of the EC-TLM signal of o-tolidine agreed very well with the current signal obtained simultaneously. The EC-TLM signal depended oil the detection point in the microchannel and was compared with distribution profiles of the oxidized species predicted by computer simulation. Under the present experimental conditions, EC-TLM could detect of the order of 10(-6) Mol dm(-3) o-tolidine in mu m-sized space with both signal-to-background and signal-to-noise ratios of 10. The results clearly showed that EC-TLM worked as expected and had adequate potential for use in sub-nano molar detection in micrometer-sized space. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 22 条
[1]   DERIVATIVE LINEAR SWEEP AND DERIVATIVE CYCLIC VOLTABSORPTOMETRY [J].
BANCROFT, EE ;
SIDWELL, JS ;
BLOUNT, HN .
ANALYTICAL CHEMISTRY, 1981, 53 (09) :1390-1394
[2]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[3]  
HATTROI A, 2003, MICRO TOTAL ANAL SYS
[4]   Water glass bonding for micro-total analysis system [J].
Ito, T ;
Sobue, K ;
Ohya, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) :187-195
[5]   Single-microparticle measurements: Laser trapping-absorption microspectroscopy under solution flow conditions [J].
Kim, HB ;
Kogi, O ;
Kitamura, N .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4338-4343
[6]  
KIM HB, 2003, MICRO TOTAL ANAL SYS, P817
[7]   Thermal lens microscopy and microchip chemistry [J].
Kitamori, T ;
Tokeshi, M ;
Hibara, A ;
Sato, K .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :52A-60A
[8]   ELECTROCHEMICAL STUDIES USING CONDUCTING GLASS INDICATOR ELECTRODES [J].
KUWANA, T ;
DARLINGTON, RK ;
LEEDY, DW .
ANALYTICAL CHEMISTRY, 1964, 36 (10) :2023-&
[9]   STUDY OF ELECTROGENERATED REACTANTS USING OPTICALLY TRANSPARENT ELECTRODES [J].
KUWANA, T ;
HEINEMAN, WR .
ACCOUNTS OF CHEMICAL RESEARCH, 1976, 9 (07) :241-248
[10]  
MANZ A, 1999, MICROSYSTEM TECHNOLO