On the Stability of Poly-Ethylenedioxythiopene as Coating Material for Active Neural Implants

被引:44
作者
Boretius, Tim [1 ]
Schuettler, Martin [1 ]
Stieglitz, Thomas [1 ]
机构
[1] Univ Freiburg, Lab Biomed Microtechnol, Dept Microsyst Engn IMTEK, D-79110 Freiburg, Germany
关键词
Poly-ethylenedioxythiopene; Electrode; Stability; Pulse test; Characterization; Functional electrical stimulation; STIMULATION;
D O I
10.1111/j.1525-1594.2011.01210.x
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
This article deals with the stability of poly-ethylenedioxythiopene (PEDOT) coatings under high loads of current pulses. Test parameters were chosen to match many peripheral nervous system applications in regard of charge injection, pulse width, and repetition frequency. PEDOT coatings were characterized with electrochemical impedance spectroscopes and pulse tests. After 60-100 million pulses, impedance increased and a more capacitive behavior was observed. A mean-time-to-failure of 127 million pulses could be calculated, suggesting a stable coating for at least this time frame with superior properties in regard of conventional platinum electrodes.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 7 条
[1]
Neural stimulation and recording electrodes [J].
Cogan, Stuart F. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :275-309
[2]
Cell attachment functionality of bioactive conducting polymers for neural interfaces [J].
Green, Rylie A. ;
Lovell, Nigel H. ;
Poole-Warren, Laura A. .
BIOMATERIALS, 2009, 30 (22) :3637-3644
[3]
MORTIMER JT, 1999, 10 NIH NEUR PROSTH P
[4]
PEIXOTO N, 2009, EMBC 2009 ANN INT C, P658
[5]
Double nerve intraneural interface implant on a human amputee for robotic hand control [J].
Rossini, Paolo M. ;
Micera, Silvestro ;
Benvenuto, Antonella ;
Carpaneto, Jacopo ;
Cavallo, Giuseppe ;
Citi, Luca ;
Cipriani, Christian ;
Denaro, Luca ;
Denaro, Vincenzo ;
Di Pino, Giovanni ;
Ferreri, Florinda ;
Guglielmelli, Eugenio ;
Hoffmann, Klaus-Peter ;
Raspopovic, Stanisa ;
Rigosa, Jacopo ;
Rossini, Luca ;
Tombini, Mario ;
Dario, Paolo .
CLINICAL NEUROPHYSIOLOGY, 2010, 121 (05) :777-783
[6]
A voltage-controlled current source with regulated electrode bias-voltage for safe neural stimulation [J].
Schuettler, Martin ;
Franke, Manfred ;
Krueger, Thilo Bernhard ;
Stieglitz, Thomas .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 171 (02) :248-252
[7]
Implantable biomedical microsystems for neural prostheses [J].
Stieglitz, T ;
Schuettler, M ;
Koch, KP .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2005, 24 (05) :58-65