Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell

被引:83
作者
Pröfrock, D [1 ]
Leonhard, P [1 ]
Prange, A [1 ]
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Coastal Res, D-21502 Geesthacht, Germany
关键词
inductively coupled plasma mass spectrometry capillary electrophoresis; hyphenation; collision cell; metallothionein; speciation; biomolecules;
D O I
10.1007/s00216-003-2041-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of sulfur in biologically relevant samples such as metalloproteins is described. The analytical methodology used is based on robust on-line coupling between capillary electrophoresis (CE) and octopole reaction cell inductively-coupled plasma mass spectrometry (ORC-ICP-MS). Polyatomic ions that form in the plasma and interfere with the determination of S at mass 32 are minimised by addition of xenon to the collision cell. The method has been applied to the separation and simultaneous element-specific detection of sulfur, cadmium, copper, and zinc in commercially available metallothionein preparations (MT) and metallothionein-like proteins (MLP) extracted from liver samples of bream (Abramis brama L.) caught in the river Elbe, Germany. Instrumental detection limits have been calculated according to the German standard procedure DIN 32645 for the determination of sulfur and some simultaneously measured trace elements in aqueous solution. For sulfur detection limits down to 1.3 mug L-1 (S-34) and 3.2 mug L-1 (S-32) were derived. For the other trace elements determined simultaneously detection limits ranging from 300 ng L-1 (Ni-58) to 500 ng L-1 (Zn-66, Mn-55) were achieved. For quantification of sulfur and cadmium in a commercially available MT preparation under hyphenated conditions the use of external calibration is suggested. Finally, the need for proper sample-preparation technique will be discussed.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 24 条
[1]   Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1497-1502
[2]   Recent developments in quantification methods for metallothionein [J].
Dabrio, M ;
Rodríguez, AR ;
Bordin, G ;
Bebianno, MJ ;
De Ley, M ;
Sestaková, I ;
Vasák, M ;
Nordberg, M .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2002, 88 (02) :123-134
[3]  
*DIN, 2645 DIN
[4]   Ion chromatographic separation of sulfur-containing inorganic anions with an ICP-MS as element-specific detector [J].
Divjak, B ;
Goessler, W .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :161-169
[5]   Sulfur-specific detection of impurities in cimetidine drug substance using liquid chromatography coupled to high resolution inductively coupled plasma mass spectrometry and electrospray mass spectrometry [J].
Evans, EH ;
Wolff, JC ;
Eckers, C .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4722-4728
[6]  
KAGI JHR, 1991, METHOD ENZYMOL, V205, P613
[7]   Correction of spectral interference of calcium in sulfur determination by inductively coupled plasma optical emission spectrometry using multiple linear regression [J].
Kola, H ;
Perämäki, P ;
Välimäki, I .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (02) :104-108
[8]   Fractionation of phosphorus and trace elements species in soybean flour and common white bean seeds by size exclusion chromatography-inductively coupled plasma mass spectrometry [J].
Koplík, R ;
Pavelková, H ;
Cincibuchová, J ;
Mestek, O ;
Kvasnicka, F ;
Suchánek, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2) :261-273
[9]   Analysis of diluted sea-water at the ng L-1 level using an ICP-MS with an octopole reaction cell [J].
Leonhard, P ;
Pepelnik, R ;
Prange, A ;
Yamada, N ;
Yamada, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) :189-196
[10]   Analysis for metallothioneins using coupled techniques [J].
Lobinski, R ;
Chassaigne, H ;
Szpunar, J .
TALANTA, 1998, 46 (02) :271-289