Stromal thermal effects induced by nonmechanical (2.94-μm) erbium:YAG laser corneal trephination

被引:12
作者
Behrens, A [1 ]
Küchle, M [1 ]
Seitz, B [1 ]
Langenbucher, A [1 ]
Kus, MM [1 ]
Amann, T [1 ]
Schlötzer-Schrehardt, U [1 ]
Rummelt, C [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-8520 Erlangen, Germany
关键词
D O I
10.1001/archopht.116.10.1342
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To determine stromal thermal changes after erbium (Er):YAG laser corneal trephination with the use of 2 open masks. Methods: Corneal trephination was performed in 89 enucleated pig eyes with an Er:YAG laser (400-microsecond pulse duration), 4 open masks (2 metallic and 2 ceramic) for both donors and recipients, and an automated globe rotation device. Different combinations of laser settings were used: pulse energy, 100, 200, and 400 mJ; repetition rate, 2 and 5 Hz; and spot size, 1.3 and 3.2 mm. Thermal effects in corneal stroma and regularity of the cut edges were quantitatively assessed by light microscopy, transmission and scanning electron microscopy. Results: Best regularity and minimal thermal effects of the cut were observed with the use of ceramic masks at 200 mJ, 2 Hz, and 3.2-mm spot size, with middepth thermal changes of 18 +/- 2 mu m. Effects increased with cut depth and were lower in donor corneas and with the use of ceramic masks (P<.001). Regularity of the cut was higher in the donors (P=.05) with lower repetition rates (P<.001). Conclusions: Even with the "free-running" Er:YAG laser mode, features of the trephination cut resembling those created by the 193-nm excimer laser along metal mask were achieved. Ceramic masks may be more suitable than metal masks. The Er:YAG laser seems to have the potential to be a compact and low-cost alternative in nonmechanical trephination for penetrating keratoplasty. Clinical Relevance: Thermal effects after corneal trephination with the free-running Er:YAG laser (2.94 mm) are limited and predictable.
引用
收藏
页码:1342 / 1348
页数:7
相关论文
共 41 条
[1]  
ALFONSO E, 1987, OPHTHALMIC SURG LAS, V18, P28
[2]  
Bende T, 1991, Fortschr Ophthalmol, V88, P12
[3]   INFLUENCE OF THE PULSE DURATION ON PHOTOABLATION WITH THE ER-YAG LASER IN OCULAR TISSUE (CORNEA AND SKLERA) [J].
BENDE, T ;
JEAN, B ;
MATALLANA, M ;
SEILER, T ;
STEINER, R .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 202 (01) :52-55
[4]  
Bende T., 1994, Ophthalmologe, V91, P651
[5]  
Cubeddu R, 1996, LASER SURG MED, V19, P32, DOI 10.1002/(SICI)1096-9101(1996)19:1<32::AID-LSM5>3.0.CO
[6]  
2-R
[7]   Comparison of suture-in and suture-out postkeratoplasty astigmatism with single running suture or combined running and interrupted sutures [J].
Filatov, V ;
Alexandrakis, G ;
Talamo, JH ;
Steinert, RF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (05) :696-700
[8]  
KAHLE G, 1991, Fortschritte der Ophthalmologie, V88, P380
[9]   Q-SWITCHED CTE-YAG (2.69 MU-M) LASER-ABLATION - BASIC INVESTIGATIONS ON SOFT (CORNEAL) AND HARD (DENTAL) TISSUES [J].
KERMANI, O ;
LUBATSCHOWSKI, H ;
ASSHAUER, T ;
ERTMER, W ;
LUKIN, A ;
ERMAKOV, B ;
KRIEGLSTEIN, GK .
LASERS IN SURGERY AND MEDICINE, 1993, 13 (05) :537-542
[10]  
Koch J W, 1991, Refract Corneal Surg, V7, P214