Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine

被引:106
作者
Deng, YZ
Henion, J
Li, JJ
Thibault, P
Wang, C
Harrison, DJ
机构
[1] Cornell Univ, New York State Coll Vet Med, Ithaca, NY 14850 USA
[2] Natl Res Council Canada, Inst Biol Sci, Ottawa, ON K1A 0R6, Canada
[3] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac0009346
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the CE separation and on-line electrospray detection of carnitine and selected acylcarnitines from mixtures of analytical standards as well as extracts of fortified human urine. Chip-based CE/MS experiments in two different. laboratories were carried out using a triple-quadrupole mass spectrometer and a quadrupole time-of-flight (QTOF) mass spectrometer, respectively. The glass chips used with both systems were comparably equipped with a microfabricated capillary electrophoresis (CE) channel but with different electro sprayers. The quadrupole chip-based CE/MS experiments employed a miniature coupled microsprayer, which allowed coupling of the microelectrospray process via a micro liquid junction at the exit of the CE capillary channel. Selected ion monitoring (SIM) CE/MS experiments were employed for all of the quadrupole CE/MS work. The QTOF CE/MS full-scan single MS and MS/MS experiments were carried out in another laboratory using accurate mass measurement TOF mass spectrometry techniques. The electrospray process that was employed with the QTOF system differed in that an inserted nano-electrospray capillary needle was carefully affixed into a hat-bottomed hole that was aligned with the CE channel exit orifice. SIM CE/MS using the described quadrupole system provided acceptable ion current electropherograms from fmole levels from analytical standard solutions of carnitine and acylcarnitines that were manually injected (loaded) onto the chip. In addition, the corresponding electropherograms for human urine fortified with the target carnitine and acylcarnitines at a 10-20 mug/mL (35-124 muM) level were obtained via SIM CE/MS techniques. The measured CE separation efficiency for the SIM CE/MS electropherograms was determined to be 2860 plates (peak width at half-height method or N = 5.54 (T/W0.5(2)), and carnitine and three acylcarnitines were separated in less than 48 s, In contrast, using quadrupole-TOF technologies, the same samples could be diluted by a factor of 2-4 to obtain a comparable detector response for the target compounds. In the full-scan, single mass analyzer mode (m/z 150-500), the CE separation efficiency was measured to be 2600 plates, but mass measurement accuracy was less than 5.0 ppm for the quaternary cations, In the CE/MS/MS mode, full-scan collision-induced dissociation (CID) mass spectra were obtained with a mass accuracy of less than or equal to 10 ppm for the higher mass ions and less than or equal to 27 ppm for the lower mass product ions. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric detection for these important compounds in synthetic mixtures, as well as in human urine extracts.
引用
收藏
页码:639 / 646
页数:8
相关论文
共 40 条
[1]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[2]   CARNITINE [J].
BIEBER, LL .
ANNUAL REVIEW OF BIOCHEMISTRY, 1988, 57 :261-283
[3]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[4]   CARNITINE - METABOLISM AND FUNCTIONS [J].
BREMER, J .
PHYSIOLOGICAL REVIEWS, 1983, 63 (04) :1420-1480
[5]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[6]   Microchip-based capillary electrophoresis of human serum proteins [J].
Colyer, CL ;
Mangru, SD ;
Harrison, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :271-276
[7]  
COVEY TR, 1986, ANAL CHEM, V58, P1451
[8]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[9]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[10]   An integrated microfluidics tandem mass spectrometry system for automated protein analysis [J].
Figeys, D ;
Gygi, SP ;
McKinnon, G ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3728-3734