Capillary electrophoresis microchips for separation and detection of organophosphate nerve agents

被引:136
作者
Wang, J [1 ]
Chatrathi, MP
Mulchandani, A
Chen, W
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
关键词
D O I
10.1021/ac001424e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analytical system for separating and detecting toxic organophosphate nerve agent compounds, based on the coupling of a micromachined capillary electrophoresis chip with a thick-film amperometric detector, is described. Factors influencing the on-chip separation and detection processes have been optimized, Using a MES buffer (20 mM, pH 5.0) running buffer, a 72-mm-long separation channel, and a separation voltage of 2000 V, baseline resolution is observed for paraoxon, methyl parathion, fenitrothion, and ethyl parathion in 140 s. Such miniaturization and speed advantages are coupled to submicromolar detection limits and good precision. Applicability to spiked river water samples is demonstrated, and the implications for on-site environmental monitoring and rapid security screening/warning are discussed.
引用
收藏
页码:1804 / 1808
页数:5
相关论文
共 17 条
[1]   Use of different surfactants (sodium dodecyl sulfate, bile salts and ionic polymers) in micellar electrokinetic capillary chromatography Application to the separation of organophosphorus pesticides [J].
Aguilar, M ;
Farran, A ;
Serra, C ;
Sepaniak, MJ ;
Whitaker, KW .
JOURNAL OF CHROMATOGRAPHY A, 1997, 778 (1-2) :201-205
[2]   Lab-on-a-chip: A revolution in biological and medical sciences. [J].
Figeys, D ;
Pinto, D .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :330A-335A
[3]   PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132
[4]   DETERMINATION OF ORGANOPHOSPHORUS AND CARBAMIC PESTICIDES WITH AN ACETYLCHOLINESTERASE AMPEROMETRIC BIOSENSOR USING 4-AMINOPHENYL ACETATE AS SUBSTRATE [J].
LAROSA, C ;
PARIENTE, F ;
HERNANDEZ, L ;
LORENZO, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :273-282
[5]   Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips [J].
Martin, RS ;
Gawron, AJ ;
Lunte, SM ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3196-3202
[6]   AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDES IN WATERS WITH DUAL ELECTROCHEMICAL (REDUCTIVE OXIDATIVE) DETECTION [J].
MARTINEZ, RC ;
GONZALO, ER ;
GARCIA, FG ;
MENDEZ, JH .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :49-58
[7]   Amperometric thick film strip electrodes for monitoring organophosphate nerve agents based on immobilized organophosphorus hydrolase [J].
Mulchandani, A ;
Mulchandani, P ;
Chen, W ;
Wang, J ;
Chen, L .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2246-2249
[8]   Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase.: 1.: Potentiometric microbial electrode [J].
Mulchandani, A ;
Mulchandani, P ;
Kaneva, I ;
Chen, W .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4140-4145
[9]   Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase.: 2.: Fiber optic microbial biosensor [J].
Mulchandani, A ;
Kaneva, I ;
Chen, W .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5042-5046
[10]   Polymeric microelectromechanical systems [J].
Soper, SA ;
Ford, SM ;
Qi, S ;
McCarley, RL ;
Kelly, K ;
Murphy, MC .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :642A-651A