Validity of the Actigraph GT3x and influence of the sensor positioning for the assessment of active energy expenditure during four activities of daily living in stroke subjects

被引:20
作者
Compagnat, Maxence [1 ,2 ]
Mandigout, Stephane [1 ]
Chaparro, David [1 ]
Daviet, Jean Christophe [1 ,2 ]
Salle, Jean Yves [1 ,2 ]
机构
[1] Univ Limoges, HAVAE, EA6310, Handicap,Aging,Auton,Environm, Limoges, France
[2] Limoges Dupuytren Univ, Hosp Ctr, Dept Phys Med & Rehabil, Limoges, France
关键词
Accelerometer; validity; energy expenditure; daily living; stroke; PHYSICAL-ACTIVITY; ACTIVITY MONITORS; WHEELCHAIR USERS; ACCELEROMETRY; RELIABILITY; PEOPLE; ADULTS;
D O I
10.1177/0269215518788116
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To explore the validity of the Actigraph and the influence of the placement of the sensor when estimating the active energy expenditure in four common daily activities (transfers, manual task, walking in overground and walking up and down stairs) in stroke survivors. Design: Cross-sectional study. Setting: Department of Physical Medicine and Rehabilitation. Subjects: A total of 46 subjects affected with stroke sequelae were wearing the Actigraph on three different locations-ankle, hip and wrist on the non-affected side-and performed four tasks: transfers, manual task, walking on flat ground and walking up and down stairs. Main measures: The values of active energy expenditure estimated by the Actigraph were compared to those measured by a portable breathing gas exchange analyzer Metamax3B. The accuracy and agreement between Actigraph and Metamax values were analyzed with mean bias, root mean square error, correlation coefficient and Bland-Altman plots for each task and each sensor location. Results: The mean bias between the Metamax and Actigraph placed on wrist, hip and ankle were, respectively, MD = 1.16 kcal (%MD = 3%), MD =-20.44 kcal (%MD =-58%) and MD = 17.64 kcal (%MD = 50%). The agreement with the Metamax was poor in general regardless of the sensor location and type of task (r = 0.12-0.58). Conclusion: This study found large differences and a poor agreement between the active energy expenditure as measured by the Actigraph and the Metamax according to the location of the sensor and the type of task performed by the subject.
引用
收藏
页码:1696 / 1704
页数:9
相关论文
共 29 条
[1]   Validity of Physical Activity Measures in Individuals After Total Knee Arthroplasty [J].
Almeida, Gustavo J. ;
Wert, David Vi. ;
Brower, Kelly S. ;
Piva, Sara R. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (03) :524-531
[2]   Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures [J].
Bassett, David R. ;
Troiano, Richard P. ;
Mcclain, James J. ;
Wolff, Dana L. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (04) :833-838
[3]   Validity of physical activity monitors in adults participating in free-living activities [J].
Berntsen, S. ;
Hageberg, R. ;
Aandstad, A. ;
Mowinckel, P. ;
Anderssen, S. A. ;
Carlsen, K-H ;
Andersen, L. B. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2010, 44 (09) :657-664
[4]   Physical Activity and Exercise Recommendations for Stroke Survivors A Statement for Healthcare Professionals From the American Heart Association/American Stroke Association [J].
Billinger, Sandra A. ;
Arena, Ross ;
Bernhardt, Julie ;
Eng, Janice J. ;
Franklin, Barry A. ;
Johnson, Cheryl Mortag ;
MacKay-Lyons, Marilyn ;
Macko, Richard F. ;
Mead, Gillian E. ;
Roth, Elliot J. ;
Shaughnessy, Marianne ;
Tang, Ada .
STROKE, 2014, 45 (08) :2532-2553
[5]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[6]  
Brun V, 2000, Ann Readapt Med Phys, V43, P14, DOI [10.1016/S0168-6054(00)87937-4, DOI 10.1016/S0168-6054(00)87937-4]
[7]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500
[8]   Comparative Validity of Physical Activity Measures in Older Adults [J].
Colbert, Lisa H. ;
Matthews, Charles E. ;
Havighurst, Thomas C. ;
Kim, Kyungmann ;
Schoeller, Dale A. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05) :867-876
[9]   Estimating energy expenditure using accelerometers [J].
Crouter, Scott E. ;
Churilla, James R. ;
Bassett, David R., Jr. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 98 (06) :601-612
[10]   MOTOR EVALUATION IN VASCULAR HEMIPLEGIA [J].
DEMEURISSE, G ;
DEMOL, O ;
ROBAYE, E .
EUROPEAN NEUROLOGY, 1980, 19 (06) :382-389