Treatment of infected tunneled venous access hemodialysis catheters with guidewire exchange

被引:93
作者
Robinson, D
Suhocki, P
Schwab, SJ
机构
[1] Duke Univ, Med Ctr, Div Nephrol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Div Vasc Radiol, Durham, NC 27710 USA
关键词
hemodialysis; bacteremia; catheters-indwelling; infection in access site; thrombosis; defervescence; antibiotics;
D O I
10.1046/j.1523-1755.1998.00954.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Cuffed venous access catheters have become commonplace for hemodialysis access. The major complications of these catheters are catheter thrombosis, catheter fibrin sheathing and infection. When catheter associated bacteremia occurs treatment with antimicrobial therapy alone has been unsuccessful in providing acceptable cure rates. Failed antimicrobial therapy exposes the patient to the risks of prolonged bacteremia, while the alternative, catheter replacement at a new site can lead to central venous stenosis and compromise future long-term upper extremity access. Catheter guidewire exchange when the tunnel tract is clinically not infected theoretically allows the preservation of future access sites and yields a higher treatment success rate while avoiding temporary non-cuffed access placement. We report a series of 23 cases of hemodialysis patients with tunneled cuffed catheters and bacteremia related to the catheter who were treated with the exchange of a new catheter over a guidewire combined with three weeks of systemic antibiotics. Patients eligible for the study required no evidence of tunnel tract infection and defervescence within 48 hours of antimicrobial therapy. Technique failure was defined as repeat infection from any organism within 90 days of catheter exchange. Four patients (18%) redeveloped bacteremia within 90 days of the exchange. The bacteremias developed at 4, 19, 63 and at 74 days days after the exchange. Guidewire exchange in combination with intravenous antibiotics in cases of catheter related bacteremia has an acceptable rate of treatment success and is a viable treatment option in a carefully selected patient population.
引用
收藏
页码:1792 / 1794
页数:3
相关论文
共 17 条
[1]   PROSPECTIVE-STUDY OF CATHETER REPLACEMENT AND OTHER RISK-FACTORS FOR INFECTION OF HYPERALIMENTATION CATHETERS [J].
ARMSTRONG, CW ;
MAYHALL, CG ;
MILLER, KB ;
NEWSOME, HH ;
SUGERMAN, HJ ;
DALTON, HP ;
HALL, GO ;
GENNINGS, C .
JOURNAL OF INFECTIOUS DISEASES, 1986, 154 (05) :808-816
[2]   Infectious rates of central venous pressure catheters: Comparison between newly placed catheters and those that have been changed [J].
Badley, AD ;
Steckelberg, JM ;
Wollan, PC ;
Thompson, RL .
MAYO CLINIC PROCEEDINGS, 1996, 71 (09) :838-846
[3]   THE USE OF DUAL LUMEN JUGULAR VENOUS CATHETERS AS DEFINITIVE LONG-TERM ACCESS FOR HEMODIALYSIS [J].
BLAKE, PG ;
HURAIB, S ;
WU, G ;
ULDALL, PR .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (01) :26-31
[4]  
BOZETTI F, 1983, ANN SURG, V198, P48
[5]   SEPTICEMIA IN LONG-TERM JUGULAR HEMODIALYSIS CATHETERS - ERADICATING INFECTION BY CHANGING THE CATHETER OVER A GUIDEWIRE [J].
CARLISLE, EJF ;
BLAKE, P ;
MCCARTHY, F ;
VAS, S ;
ULDALL, R .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) :150-153
[6]  
FAN PY, 1992, J AM SOC NEPHROL, V3, P1
[7]  
Kovalik EC, 1996, J AM SOC NEPHROL, V7, P2264
[8]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+
[9]   USE OF A SILICONE DUAL-LUMEN CATHETER WITH A DACRON CUFF AS A LONG-TERM VASCULAR ACCESS FOR HEMODIALYSIS-PATIENTS [J].
MOSS, AH ;
VASILAKIS, C ;
HOLLEY, JL ;
FOULKS, CJ ;
PILLAI, K ;
MCDOWELL, DE .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 16 (03) :211-215
[10]  
NKF-DOQI, 1997, AM J KIDNEY DIS S3, V30, pS150