Atmospheric trace gas measurements using a dual quantum-cascade laser n-dd-infrared absorption spectrometer

被引:43
作者
Jiménez, R [1 ]
Herndon, S [1 ]
Shorter, JH [1 ]
Nelson, DD [1 ]
McManus, JB [1 ]
Zahniser, MS [1 ]
机构
[1] Harvard Univ, Dept Earth Planetary Sci, Cambridge, MA 02138 USA
来源
NOVEL IN-PLANE SEMICONDUCTOR LASERS IV | 2005年 / 5738卷
关键词
CONTINUOUS-WAVE OPERATION; IN-SITU MEASUREMENTS; NITROUS-OXIDE; FAST-RESPONSE; AIRCRAFT; EMISSION; METHANE; SENSOR; NO2; CH4;
D O I
10.1117/12.597130
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present an overview of the dual QC laser spectrometer developed at Aerodyne Research and various examples of its application for atmospheric trace gas detection. The instrument incorporates two pulsed QC lasers, a compact 76-m (or 56-m) multipass absorption cell, a dual HgCdTe detector, and a sophisticated signal generation, data acquisition and processing system. Recent findings and hardware innovations are highlighted. Our results show that the precision and minimal detectable absorbance obtainable with pulsed QC lasers are comparable to those achieved with cryogenically cooled CW Pb-salt lasers in spite of the broader laser linewidths inherent to pulsed operation. This is demonstrated through in situ measurements of several trace gases, including methane, nitrous oxide, carbon monoxide, formaldehyde, formic acid, nitrous acid and ethylene. Recent measurements of HCHO and HCOOH on board a NOAA aircraft are presented. The precision, stability and intrinsic accuracy of the instrument were assessed through inter-comparisons measuring CH4 and CO. These measurements were made either comparing two QC lasers sweeping over different transitions or comparing the dual QCL spectrometer and a standard instrument (NDIR CO). The absorbance precision achieved is typically 2 x 10(-5) Hz(-1/2). For long-lived species, such as CH4 and N2O, this implies 1-Hz fractional precisions of 0.1% or better, which fulfill the requirement for meaningful measurements from aircraft platforms. Spectroscopically derived mixing ratios are accurate within 5% or better. The spectrometer is equipped to perform automatic, periodic calibrations with zero and span gases whenever higher accuracy is required.
引用
收藏
页码:318 / 331
页数:14
相关论文
共 42 条
[1]   Continuous wave operation of a mid-infrared semiconductor laser at room temperature [J].
Beck, M ;
Hofstetter, D ;
Aellen, T ;
Faist, J ;
Oesterle, U ;
Ilegems, M ;
Gini, E ;
Melchior, H .
SCIENCE, 2002, 295 (5553) :301-305
[2]   Laser-spectroscopic investigation of OH-radical concentrations in the exhaust plane of jet engines [J].
Böckle, S ;
Einecke, S ;
Hildenbrand, F ;
Orlemann, C ;
Schulz, C ;
Wolfrum, J ;
Sick, V .
GEOPHYSICAL RESEARCH LETTERS, 1999, 26 (13) :1849-1852
[3]   Quantum cascade lasers: Ultrahigh-Speed operation, optical wireless communication, narrow linewidth, and far-infrared emission [J].
Capasso, F ;
Paiella, R ;
Martini, R ;
Colombelli, R ;
Gmachl, C ;
Myers, TL ;
Taubman, MS ;
Williams, RM ;
Bethea, CG ;
Unterrainer, K ;
Hwang, HY ;
Sivco, DL ;
Cho, AY ;
Sergent, AM ;
Liu, HC ;
Whittaker, EA .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2002, 38 (06) :511-532
[4]  
Dicki D., 1998, Tech. Rep. NASA/TM-1998-208509
[5]   EMISSION MEASUREMENTS OF THE CONCORDE SUPERSONIC AIRCRAFT IN THE LOWER STRATOSPHERE [J].
FAHEY, DW ;
KEIM, ER ;
BOERING, KA ;
BROOK, CA ;
WILSON, JC ;
JONSSON, HH ;
ANTHONY, S ;
HANISCO, TF ;
WENNBERG, PO ;
MIAKELYE, RC ;
SALAWITCH, RJ ;
LOUISNARD, N ;
WOODBRIDGE, EL ;
GAO, RS ;
DONNELLY, SG ;
WAMSLEY, RC ;
DELNEGRO, LA ;
SOLOMON, S ;
DAUBE, BC ;
WOFSY, SC ;
WEBSTER, CR ;
MAY, RD ;
KELLY, KK ;
LOEWENSTEIN, M ;
PODOLSKE, JR ;
CHAN, KR .
SCIENCE, 1995, 270 (5233) :70-74
[6]   Room temperature mid-infrared quantum cascade lasers [J].
Faist, J ;
Capasso, F ;
Sirtori, C ;
Sivco, DL ;
Hutchinson, AL ;
Cho, AY .
ELECTRONICS LETTERS, 1996, 32 (06) :560-561
[7]   QUANTUM CASCADE LASER [J].
FAIST, J ;
CAPASSO, F ;
SIVCO, DL ;
SIRTORI, C ;
HUTCHINSON, AL ;
CHO, AY .
SCIENCE, 1994, 264 (5158) :553-556
[8]   Distributed feedback quantum cascade lasers [J].
Faist, J ;
Gmachl, C ;
Capasso, F ;
Sirtori, C ;
Sivco, DL ;
Baillargeon, JN ;
Cho, AY .
APPLIED PHYSICS LETTERS, 1997, 70 (20) :2670-2672
[9]   Laboratory, ground-based, and airborne tunable diode laser systems: performance characteristics and applications in atmospheric studies [J].
Fried, A ;
Henry, B ;
Wert, B ;
Sewell, S ;
Drummond, JR .
APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03) :317-330
[10]   Tunable diode laser absorption spectrometer for ground-based measurements of formaldehyde [J].
Fried, A ;
Sewell, S ;
Henry, B ;
Wert, BP ;
Gilpin, T ;
Drummond, JR .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D5) :6253-6266