Comparison of single-shot east spin-echo and conventional spin-echo sequences for MR imaging of the heart: Initial experience

被引:27
作者
Vignaux, OB
Augui, J
Coste, J
Argaud, C
Le Roux, P
Carlier, PG
Duboc, D
Legmann, P
机构
[1] Univ Paris 05, Hop Cochin, Dept Radiol, F-75679 Paris 14, France
[2] Univ Paris 05, Hop Cochin, Dept Biostat, F-75679 Paris, France
[3] Univ Paris 05, Hop Cochin, Dept Cardiol, F-75679 Paris 14, France
[4] Serv Hosp Frederic Joliot, Orsay, France
[5] GE Med Syst, Buc, France
关键词
heart; diseases; MR; magnetic resonance (MR); rapid imaging; technology;
D O I
10.1148/radiology.219.2.r01ma27545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A conventional T1 -weighted spin-echo (SE) magnetic resonance (MR) imaging sequence was compared with breath-hold and non-breath-hold half-Fourier single-shot fast SE MR sequences with black-blood preparation and high spatial resolution for imaging of various cardiac diseases. The optimized single-shot fast SE sequence provided better or equal image quality in less time. Breath-hold and non-breath-hold single-shot fast SE sequences may replace the conventional T1-weighted SE sequence for first-line cardiac MR imaging.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 13 条
[1]   Diagnosis of cardiac sarcoidosis aided by MRI [J].
Chandra, M ;
Silverman, ME ;
Oshinski, O ;
Pettigrew, R .
CHEST, 1996, 110 (02) :562-565
[2]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[3]   ACUTE MYOCARDIAL-INFARCTION - MR EVALUATION IN 29 PATIENTS [J].
FISHER, MR ;
MCNAMARA, MT ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :247-251
[4]   USEFULNESS OF MAGNETIC-RESONANCE-IMAGING FOR DIAGNOSIS OF ACUTE MYOCARDITIS IN INFANTS AND CHILDREN, AND COMPARISON WITH ENDOMYOCARDIAL BIOPSY [J].
GAGLIARDI, MG ;
BEVILACQUA, M ;
DIRENZI, P ;
PICARDO, S ;
PASSARIELLO, R ;
MARCELLETTI, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (10) :1089-1091
[5]   T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES [J].
HADDAD, JL ;
ROFSKY, NM ;
AMBROSINO, MM ;
NAIDICH, DP ;
WEINREB, JC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03) :325-329
[6]  
LAUB G, 1995, P SOC MAGN RES MED E, P246
[7]   Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging [J].
Le Roux, P ;
Gilles, RJ ;
McKinnon, GC ;
Carlier, PG .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1022-1032
[8]   CARDIAC MASSES - SIGNAL INTENSITY FEATURES ON SPIN-ECHO, GRADIENT-ECHO, GADOLINIUM-ENHANCED SPIN-ECHO, AND TURBOFLASH IMAGES [J].
SEMELKA, RC ;
SHOENUT, JP ;
WILSON, ME ;
PELLECH, AE ;
PATTON, JN .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04) :415-420
[9]   HASTE MR imaging: Description of technique and preliminary results in the abdomen [J].
Semelka, RC ;
Kelekis, NL ;
Thomasson, D ;
Brown, MA ;
Laub, GA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :698-699
[10]   ''Black blood'' T2-weighted inversion-recovery MR imaging of the heart [J].
Simonetti, OP ;
Finn, JP ;
White, RD ;
Laub, G ;
Henry, DA .
RADIOLOGY, 1996, 199 (01) :49-57