Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant

被引:96
作者
Ricci, WM
Bolhofner, BR
Loftus, T
Cox, C
Mitchell, S
Borrelli, J
机构
[1] Washington Univ, Barnes Jewish Hosp, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] All Florida Orthopaed Associates, St Petersburg, FL USA
关键词
D O I
10.2106/JBJS.D.01911
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The application of indirect reduction techniques has improved fracture-healing and reduced the need for bone-grafting compared with the outcomes of older, direct reduction techniques. We investigated the results of such indirect reduction techniques for the treatment of periprosthetic femoral shaft fractures. Methods: Fifty consecutive patients with a femoral shaft fracture about a stable intramedullary implant (a Vancouver Type-B1 fracture) were treated with a protocol that included open reduction with use of indirect reduction techniques and internal fixation with a single lateral plate without structural allografting or other bone-grafting. Four patients died in the early postoperative period, and five had inadequate follow-up. The remaining forty-one patients (average age, seventy-two years) were evaluated clinically and radiographically at an average of twenty-four months. Results: All fractures healed in satisfactory alignment at an average of twelve weeks (range, seven to twenty-three weeks) after the index procedure. One patient had one fractured cable and two others had one fractured screw, but all of the fractures healed without evidence of implant loosening or malalignment. There was one deep infection in the perioperative period. Thirty of the forty-one patients returned to their baseline ambulatory status. Conclusions: The results of this study support the use of indirect open reduction and internal fixation with a single extraperiosteal lateral plate, without the use of allograft struts, for the treatment of a femoral shaft fracture about a stable intramedullary implant.
引用
收藏
页码:2240 / 2245
页数:6
相关论文
共 20 条
[1]
Percutaneous plate fixation for periprosthetic femoral fractures - a preliminary report [J].
Abhaykumar, S ;
Elliott, DS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (08) :627-630
[2]
The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :249-+
[3]
Chandler H P, 1993, Semin Arthroplasty, V4, P99
[4]
Chandler HP, 1998, AAOS INSTR COURS LEC, V47, P257
[5]
*COMM COD CLASS OR, 1996, J ORTHOP TRAUMA S1, V10, P154
[6]
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
[7]
Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate [J].
Haddad, FS ;
Duncan, CP ;
Berry, DJ ;
Lewallen, DG ;
Gross, AE ;
Chandler, HP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06) :945-950
[8]
The Dall-Miles cable and plate system for periprosthetic femoral fractures [J].
Haddad, FS ;
Marston, RA ;
Muirhead-Allwood, SK .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (07) :445-447
[10]
REVISION THR AFTER PERIPROSTHETIC FEMORAL FRACTURES - AN ANALYSIS OF 23 CASES [J].
KOLSTAD, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (05) :505-508