Relationship of A1C to glucose concentrations in children with type 1 diabetes - Assessments by high-frequency glucose determinations by sensors

被引:85
作者
Wilson, Darrell M. [1 ]
Kollman, Craig [1 ]
Xing, Dongyuan [1 ]
Fiallo-Scharer, Rosanna [1 ]
Weinzimer, Stuart [1 ]
Steffes, Michael [1 ]
Wysocki, Tim [1 ]
Beck, Roy [1 ]
Ruedy, Katrina [1 ]
Tamborlane, William [1 ]
机构
[1] Jaeb Ctr Hlth Res, DirecNet Coordinating Ctr, Tampa, FL 33647 USA
关键词
D O I
10.2337/dc07-1835
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - Despite the standing of A1C as the most validated and widely used measure for average glycemic control over time, the relationship between A1C and glucose concentrations is not completely understood. The purpose of this Diabetes Research in Children Network (DirecNet) study was to use continuous glucose monitoring data to examine the relationship between A1C and glucose in type 1 diabetes. RESEARCH DESIGN AND METHODS - Forty-eight youth enrolled in studies of the Navigator continuous glucose monitor were encouraged to wear the Navigator sensor at home continuously. A1C was measured at baseline, at 3 months, and at 6 months. Sensor glucose data were directly transmitted via the Internet, assuring that essentially all glucose values were analyzed. RESULTS - Subjects had a median of 112 h/week of Navigator data in the first 3 months and 115 h/week in the second 3 months. The slope of mean glucose over the previous 3 months versus A1C was only 18 mg/dl per 1.0% A1C. Individually, there was substantial variation in the relationship between mean glucose and A1C. A1C was not associated with glucose lability after controlling for mean glucose. Measures of an individual's rate of glycation were moderately correlated at the 3- and 6-month visits. CONCLUSIONS - As the chemistry of glycation would predict, we found no evidence to contradict the simple hypothesis that A1C directly reflects mean glucose over time. There is, however, substantial variability in individual mean glucose concentrations for a given A1C. Transforming reliable A1C values into calculated mean glucose values would, when applied to an individual, introduce substantial error.
引用
收藏
页码:381 / 385
页数:5
相关论文
共 16 条
[1]   Nonfasting plasma glucose is a better marker of diabetic control than fasting plasma glucose in type 2 diabetes [J].
Avignon, A ;
Radauceanu, A ;
Monnier, L .
DIABETES CARE, 1997, 20 (12) :1822-1826
[2]   Is poor, glycemic control associated with reduced red blood cell lifespan? [J].
Cohen, RM ;
Franco, R ;
Joiner, CH .
DIABETES CARE, 2004, 27 (04) :1013-1014
[3]   Evidence for independent heritability of the glycation gap, (glycosylation gap) fraction of HbA1c in nondiabetic twins [J].
Cohen, Robert M. ;
Snieder, Harold ;
Lindsell, Christopher J. ;
Beyan, Huriya ;
Hawa, Mohammed I. ;
Blinko, Stuart ;
Edwards, Raymond ;
Spector, Timothy D. ;
Leslie, R. David G. .
DIABETES CARE, 2006, 29 (08) :1739-1743
[4]  
*DIAB RES CHILDR N, 2005, PEDIAT DIABETES, V6, P13
[5]   Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes [J].
Fiallo-Scharer, R ;
Xing, DY ;
Weinzimer, S ;
Buckingham, B ;
Mauras, N ;
Tansey, M ;
Chase, P ;
Beck, R ;
Ruedy, K ;
Kollman, C ;
Tamborlane, W ;
Chase, HP ;
Fiallo-Scharer, R ;
Fisher, JH ;
Tallant, B ;
Tsalikian, E ;
Tansey, MJ ;
Larson, LF ;
Coffey, J ;
Wysocki, T ;
Mauras, N ;
Fox, LA ;
Bird, K ;
Lofton, KL ;
Buckingham, BA ;
Wilson, DM ;
Block, JM ;
Clinton, P ;
Weinzimer, SA ;
Tamborlane, WV ;
Doyle, EA ;
Sikes, K ;
Beck, RW ;
Ruedy, KJ ;
Kollman, C ;
Xing, DY ;
Kalajian, A ;
Silvester, CR ;
Steffes, MW ;
Bucksa, JM ;
Nowicki, ML ;
Van Hale, CA ;
Grave, GD ;
Linder, B ;
Winer, KK ;
Becker, DM ;
Cox, C ;
Ryan, CM ;
White, NH ;
White, PC .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (06) :3387-3391
[6]   Diabetes epidemiology: Guiding clinical and public health practice - The Kelly West Award Lecture, 2006 [J].
Herman, William H. .
DIABETES CARE, 2007, 30 (07) :1912-1919
[7]   Consensus statement on the worldwide standardization of the hemoglobin A1C measurement - The American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation [J].
Hicks, Jocelyn ;
Muller, Mathias ;
Panteghini, Mauro ;
John, Garry ;
Deeb, Larry ;
Buse, John ;
Nathan, David M. ;
Kahn, Richard ;
Ferrannini, Ele ;
Heine, Robert ;
Silink, Martin ;
Mbanya, Jean-Claude .
DIABETES CARE, 2007, 30 (09) :2399-2400
[8]   What is the relative contribution of blood glucose levels at different time points of the day to HbA1c in Type 1 diabetes? [J].
Hillman, N ;
Herranz, L ;
Grande, C ;
Vaquero, PM ;
Pallardo, LF .
DIABETIC MEDICINE, 2004, 21 (05) :468-470
[9]  
Kovatchev Boris P, 2005, Diabetes Technol Ther, V7, P849, DOI 10.1089/dia.2005.7.849
[10]   The hemoglobin glycation index is not an independent predictor of the risk of microvascular complications in the diabetes control and complications trial [J].
Lachin, John M. ;
Genuth, Saul ;
Nathan, David M. ;
Rutledge, Brandy N. .
DIABETES, 2007, 56 (07) :1913-1921