Ageing of nickel used as sensitive material for early detection of sudomotor dysfunction

被引:6
作者
Ayoub, Hanna [2 ,3 ]
Lair, Virginie [2 ]
Griveau, Sophie [3 ]
Galtayries, Anouk [1 ]
Brunswick, Philippe
Bedioui, Fethi [3 ]
Cassir, Michel [2 ]
机构
[1] Chim ParisTech, LPCS, CNRS ENSCP UMR 7045, F-75231 Paris 05, France
[2] Chim ParisTech, LECIME, CNRS ENSCP UMR 7575, F-75231 Paris 05, France
[3] Univ Paris 05, Unite Pharmacol Chim & Genet & Imagerie, CNRS 8151, CNRS 8151,INSERM,U 1022, F-75231 Paris 05, France
关键词
Nickel; Ni ageing; Nickel oxide; XPS; ToF-SIMS; Electrochemistry; Chloride; Physiological pH; Synthetic sweat; PITTING CORROSION; PASSIVE FILMS; TOF-SIMS; XPS; GROWTH; OXIDE; BASE; BREAKDOWN; PHOSPHATE; METALS;
D O I
10.1016/j.apsusc.2011.10.123
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The surface ageing of nickel electrodes was studied in the frame of the development of non-invasive biomedical devices, dedicated to the detection of sudomotor dysfunction manifested by an alteration of the ionic balance in human sweat. In this kind of technology, low voltage potentials with variable amplitudes are applied to nickel electrodes, placed on skin regions with a high density of sweat glands, and the electrical responses are measured. The trick is that nickel electrodes play alternately the role of anode and cathode, thus the analysis of the temporal evolution of the physico-chemical properties of nickel is of prime importance to ensure the good performance of the device. Electrochemical measurements coupled to surface chemical characterizations (X-ray photoelectron spectroscopy (XPS), Time of Flight-Secondary Ion Mass Spectrometry (ToF-SIMS)) were performed on pure Ni samples, immersed in buffered chloride solutions mimicking human sweat. The shapes of voltammograms, recorded in a restricted anodic potential range, show that the nickel surface was gradually passivated as a function of the number of scans. This was confirmed by XPS data, with the formation of a 1 nm thick duplex layer composed by nickel hydroxide (outermost layer) and nickel oxide (inner layer). In a negative extended potential range, though the electrochemical behavior of electrodes was not modified upon cycling the potential, XPS data show that the inner layer was thickening, indicating a surface degradation of the nickel electrode. Below pitting potentials, adsorbed chloride was only hardly detected by XPS, and the surface composition of the nickel samples was similar after treatments in chloride or chloride-free buffered solutions. In a larger potential range enabling to reach the breakdown potential, the highly chemically sensitive ToF-SIMS characterization pointed out that the surface concentration of adsorbed chloride was higher in pits than elsewhere on the surface sample. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2724 / 2731
页数:8
相关论文
共 23 条
[1]   Investigation of the HCl (g) attack on pre-oxidized pure Fe, Cr, Ni and commercial 304 steel at 400 °C [J].
Asteman, H. ;
Spiegel, M. .
CORROSION SCIENCE, 2007, 49 (09) :3626-3637
[2]  
Ayoub H., SENS LETT J IN PRESS
[3]   Electrochemical Characterization of Nickel Electrodes in Phosphate and Carbonate Electrolytes in View of Assessing a Medical Diagnostic Device for the Detection of Early Diabetes [J].
Ayoub, Hanna ;
Griveau, Sophie ;
Lair, Virginie ;
Brunswick, Philippe ;
Cassir, Michel ;
Bedioui, Fethi .
ELECTROANALYSIS, 2010, 22 (21) :2483-2490
[4]   X-ray photoelectron spectroscopic chemical state quantification of mixed nickel metal, oxide and hydroxide systems [J].
Biesinger, Mark C. ;
Payne, Brad P. ;
Lau, Leo W. M. ;
Gerson, Andrea ;
Smart, Roger St. C. .
SURFACE AND INTERFACE ANALYSIS, 2009, 41 (04) :324-332
[5]  
Brunswick P., 2008, Patent number, France, Patent No. 0753461
[6]   VOLTAMMETRIC BEHAVIOR OF NICKEL IN BASE WITH PARTICULAR REFERENCE TO THICK OXIDE-GROWTH [J].
BURKE, LD ;
TWOMEY, TAM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 162 (1-2) :101-119
[7]   GROWTH OF AN ELECTROCHROMIC FILM ON NICKEL IN BASE UNDER POTENTIAL CYCLING CONDITIONS [J].
BURKE, LD ;
WHELAN, DP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 109 (1-3) :385-388
[8]   XPS characterization of the corrosion film formed on the electroless nickel deposit prepared using different stabilizers in NaCl solution [J].
Cheong, Woo-Jae ;
Luan, Ben L. ;
McIntyre, N. S. ;
Shoesmith, David W. .
SURFACE AND INTERFACE ANALYSIS, 2007, 39 (05) :405-414
[9]   MANY-ELECTRON SINGULARITY IN X-RAY PHOTOEMISSION AND X-RAY LINE SPECTRA FROM METALS [J].
DONIACH, S ;
SUNJIC, M .
JOURNAL OF PHYSICS PART C SOLID STATE PHYSICS, 1970, 3 (02) :285-&
[10]   Mechanisms for pitting corrosion in alloy N04400 as revealed by imaging XPS, ToF-SIMS and low-voltage SEM [J].
Francis, JT ;
McIntyre, NS ;
Davidson, RD ;
Ramamurthy, S ;
Brennenstühl, AM ;
McBride, A ;
Roberts, A .
SURFACE AND INTERFACE ANALYSIS, 2002, 33 (01) :29-34