Purpose: We describe state-of-the-art software and hardware requirements for the manufacture of high quality medical models manufactured using medical rapid prototyping. The limitations of medical models, the source of artefacts, and their physical appearance are illustrated along with remedies for their removal. Materials and Methods: Medical models were built using predominantly stereolithography and fused deposition modeling at both institutions over a period of 6 years. A combined total of 350 models have been produced for a range of maxillofacial, neurosurgical, and orthopedic applications. Stereolithography, fused deposition modeling, computerized numerical milling, and other technologies are described along with computer software requirements. Results: A range of unwanted artefacts that create distortions on medical models have been identified. These include data import, computed tomography gantry distortion, metal, motion, surface roughness due to support structure removal or surface modeling, and image data thresholding. The source of the artefact has been related to the patient, imaging modality performance, or the modeling technology. Discussion as to the significance of the artefacts on clinical use is provided. Conclusions: It is recommended that models of human anatomy generated by medical rapid prototyping are subject to rigorous quality assurance at all stages of the manufacturing process. Clinicians should be aware of potential areas for inaccuracies within models and review the source images in cases where model integrity is in doubt. (C) 2005 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1006 / 1015
页数:10
相关论文
共 32 条
[1]   CT-GUIDED STEREOLITHOGRAPHY AS A NEW TOOL IN CRANIOFACIAL SURGERY [J].
ANDERL, H ;
NEDDEN, DZ ;
MUHLBAUER, W ;
TWERDY, K ;
ZANON, E ;
WICKE, K ;
KNAPP, R .
BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (01) :60-64
[2]   MAXILLOFACIAL BIOMODELLING [J].
ARVIER, JF ;
BARKER, TM ;
YAU, YY ;
DURSO, PS ;
ATKINSON, RL ;
MCDERMANT, GR .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1994, 32 (05) :276-283
[3]  
Barker T M, 1994, Australas Radiol, V38, P106, DOI 10.1111/j.1440-1673.1994.tb00146.x
[4]   Preliminary experience with medical applications of rapid prototyping by selective laser sintering [J].
Berry, E ;
Brown, JM ;
Connell, M ;
Craven, CM ;
Efford, ND ;
Radjenovic, A ;
Smith, MA .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (01) :90-96
[5]   Analysis of errors in medical rapid prototyping models [J].
Choi, JY ;
Choi, JH ;
Kim, NK ;
Kim, Y ;
Lee, JK ;
Kim, MK ;
Lee, JH ;
Kim, MJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) :23-32
[6]  
Chua CK, 1997, RAPID PROTOTYPING J, V3, P116
[7]   Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial [J].
D'Urso, PS ;
Barker, TM ;
Earwaker, WJ ;
Bruce, LJ ;
Atkinson, RL ;
Lanigan, MW ;
Arvier, JF ;
Effeney, DJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) :30-37
[8]  
ERBEN C, 2000, PHIDIAS NEWSLETTER, V5, P60
[9]   Individual prefabricated titanium implants in reconstructive craniofacial surgery:: Clinical and technical aspects of the first 22 cases [J].
Eufinger, H ;
Wehmöller, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (02) :300-308
[10]   Stair-step artifacts with single versus multiple detector-row helical CT [J].
Fleischmann, D ;
Rubin, GD ;
Paik, DS ;
Yen, SY ;
Hilfiker, PR ;
Beaulieu, CF ;
Napel, S .
RADIOLOGY, 2000, 216 (01) :185-196