Rapid screening method for diuretics in doping control using automated solid phase extraction and liquid chromatography-electrospray tandem mass spectrometry

被引:69
作者
Goebel, C [1 ]
Trout, GJ [1 ]
Kazlauskas, R [1 ]
机构
[1] Australian Govt Analyt Labs, Australian Sports Drug Testing Lab, Pymble, NSW 2073, Australia
关键词
diuretics; urine; doping; LC-MS-MS; SPE;
D O I
10.1016/j.aca.2003.09.062
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A new method has been developed for the routine detection of diuretics in urine samples collected from athletes. The method developed uses automated solid phase extraction (SPE) with analysis of the extracts by high performance liquid chromatography using electrospray ionisation tandem mass spectrometry. It requires only one injection per sample and is currently capable of detecting 35 diuretics and related compounds at the rate of five samples per hour. All parent compounds can be detected at urinary concentrations significantly below 100 ng/ml with the recovery of most analytes being greater than 80%. Crown Copyright (C) 2003 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 16 条
[1]
Rapid determination of diuretics in human urine by gas chromatography-mass spectrometry following microwave assisted derivatization [J].
Amendola, L ;
Colamonici, C ;
Mazzarino, M ;
Botrè, F .
ANALYTICA CHIMICA ACTA, 2003, 475 (1-2) :125-136
[2]
COMPREHENSIVE SCREENING-PROCEDURE FOR DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, SF ;
MASSE, R ;
DUGAL, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :65-88
[3]
Screening for 18 diuretics and probenecid in doping analysis by liquid chromatography-tandem mass spectrometry [J].
Deventer, K ;
Delbeke, FT ;
Roels, K ;
Van Eenoo, P .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (08) :529-535
[4]
FOURACRE C, 2001, RECENT ADV DOPING AN, V9, P321
[5]
A high performance liquid chromatographic method for the screening of 17 diuretics in human urine [J].
Guchelaar, HJ ;
Chandi, L ;
Schouten, O ;
van den Brand, WA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (07) :700-705
[6]
International Olympic Committee (IOC), 2001, PROH CLASS SUBST PRO, V2001
[7]
KAZLAUSKAS R, 2002, CLIN BIOCHEM REV, V23, P35
[8]
DIURETIC SCREENING IN HUMAN URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY - USE OF A MACRORETICULAR ACRYLIC COPOLYMER FOR THE EFFICIENT REMOVAL OF THE COEXTRACTED PHASE-TRANSFER REAGENT AFTER DERIVATIZATION BY DIRECT EXTRACTIVE ALKYLATION [J].
LISI, AM ;
KAZLAUSKAS, R ;
TROUT, GJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 581 (01) :57-63
[9]
Increasing sample throughput in pharmacological studies by using dual-column liquid chromatography with tandem mass spectrometry [J].
Oertel, R ;
Richter, K ;
Fauler, J ;
Kirch, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :187-192
[10]
SYSTEMATIC ANALYSIS OF DIURETIC DOPING AGENTS BY HPLC SCREENING AND GC/MS CONFIRMATION [J].
PARK, SJ ;
PYO, HS ;
KIM, YJ ;
KIM, MS ;
PARK, JS .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (02) :84-90