Helical CT examination of potential kidney donors

被引:45
作者
Dachman, AH
Newmark, GM
Mitchell, MT
Woodle, ES
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Surg, Chicago, IL 60637 USA
关键词
D O I
10.2214/ajr.171.1.9648788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate helical CT using axial, coronal, and three-dimensional (3D) reconstruction in the examination of potential kidney donors and to compare the results with angiography and surgery when possible. We also reviewed previously published reports. SUBJECTS AND METHODS. Thirty-six patients underwent unenhanced and enhanced helical CT (3-mm collimation, 150-170 mi of IV contrast material injected at 4 ml/sec; pitch 1.5; 17-sec scan delay) with coronal and 3D shaded-surface-display reconstructions made from 1.5-mm overlapping reconstructions. All CT scans were interpreted independently of each other by two observers unaware of other findings. A third observer, who was aware of other findings, also interpreted the images. Results were compared with angiography (24 cases) and surgery (24 cases). Our results are compared with those of other investigators. RESULTS. Axial CT was the best method for detecting accessory arteries (24%) and early branching (10%); it also detected relevant venous and ureteral anatomy and incidental findings. The coronal and 3D images rarely added information that resulted in changed patient treatment. CT findings were concordant with those of digital angiography in 89% of kidneys and were 98% concordant with surgery. CONCLUSION. Helical CT can show arterial, venous, and ureteral anatomy and can also show important incidental findings. Lf only helical CT is used, a few small accessory vessels and an occasional renal artery stenosis may be missed. Axial images are generally diagnostic and may be supplemented by multiplanar and 3D images read concurrently.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 16 条
[1]   Helical CT angiography for examination of living renal donors [J].
Cochran, ST ;
Krasny, RM ;
Danovitch, GM ;
Rajfer, J ;
Barbaric, ZM ;
Wilkinson, A ;
Rosenthal, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1569-1573
[2]  
DERAUF B, 1987, RADIOL CLIN N AM, V25, P261
[3]   100 LIVING-RELATED KIDNEY DONOR EVALUATIONS USING DIGITAL SUBTRACTION ANGIOGRAPHY [J].
FLECHNER, SM ;
SANDLER, CM ;
HOUSTON, GK ;
VANBUREN, CT ;
LORBER, MI ;
KAHAN, BD .
TRANSPLANTATION, 1985, 40 (06) :675-678
[4]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[5]  
Lowell J A, 1994, Semin Urol, V12, P102
[6]   Helical CT evaluation of potential kidney donors: Findings in 154 subjects [J].
Platt, JF ;
Ellis, JH ;
Korobkin, M ;
Reige, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1325-1330
[7]   Potential renal donors: Comparison of conventional imaging with helical CT [J].
Platt, JF ;
Ellis, JH ;
Korobkin, M ;
Reige, KA ;
Konnak, JW ;
Leichtman, AB .
RADIOLOGY, 1996, 198 (02) :419-423
[8]   SELECTION CRITERIA FOR THE EVALUATION OF LIVING RELATED RENAL DONORS [J].
RIEHLE, RA ;
STECKLER, R ;
NASLUND, EB ;
RIGGIO, R ;
CHEIGH, J ;
STUBENBORD, W .
JOURNAL OF UROLOGY, 1990, 144 (04) :845-848
[9]   ASSESSMENT OF LIVING RENAL DONORS WITH SPIRAL CT [J].
RUBIN, GD ;
ALFREY, EJ ;
DAKE, MD ;
SEMBA, CP ;
SOMMER, FG ;
KUO, PC ;
DAFOE, DC ;
WASKERWITZ, JA ;
BLOCH, DA ;
JEFFREY, RB .
RADIOLOGY, 1995, 195 (02) :457-462
[10]   SPIRAL CT OF RENAL-ARTERY STENOSIS - COMPARISON OF 3-DIMENSIONAL RENDERING TECHNIQUES [J].
RUBIN, GD ;
DAKE, MD ;
NAPEL, S ;
JEFFREY, RB ;
MCDONNELL, CH ;
SOMMER, FG ;
WEXLER, L ;
WILLIAMS, DM .
RADIOLOGY, 1994, 190 (01) :181-189