Multicentric reference values for some quantities measured with the Elecsys 2010® analyser

被引:13
作者
Fuentes-Arderiu, X [1 ]
Ferrer-Masferrer, M
González-Alba, JM
Villarino-González, MI
Arrimadas-Esteban, E
Cabrero-Olivé, D
Cándenas-Arroyo, M
García-García, D
García-Lario, JV
Idoate-Cervantes, I
León-López, C
López-Lazareno, N
Mar-Medina, C
Martí-Marcet, I
Mauri-Dot, M
Pérez-Valero, V
Reta-Manterola, A
Sánchez-Eixeres, MR
机构
[1] Ciutat Sanitaria & Univ Bellvitge, Serv Bioquim Clin, Lhopitalet De Llobregat, Catalonia, Spain
[2] Roche Diagnost SL, Barcelona, Catalonia, Spain
[3] Hosp SAS de la Linea, Lab Anal Clin, Andalucia, Spain
[4] Hosp Dr Josep Trueta, Serv Bioquim, Girona, Catalonia, Spain
[5] Hosp San Agustin, Lab Anal Clin, Aviles, Asturias, Spain
[6] Complejo Hosp N Sra de la Candelaria, Serv Bioquim, Santa Cruz De Tenerife, Canary Isl, Spain
[7] Clin Hosp Motril, Lab Anal, Andalucia, Spain
[8] Hosp Virgen Camino, Serv Bioquim, Navarra, Spain
[9] Hosp Gen Univ Gregorio Maranon, Serv Bioquim, Madrid, Spain
[10] Consorci Sanitari Terrassa, Lab Anal Clin, Galdakato, Basque Country, Spain
[11] Hosp Gen Univ Alacant, Lab Anal Clin, Alacant, Valencian Count, Spain
关键词
reference values; thyroid hormones; cobalamines; folates; Elecsys 2010 (R);
D O I
10.1016/S0009-8981(00)00406-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Several clinical laboratories in different regions of Spain have shared this search for reference individuals and the production of reference values for quantities concerning thyrotropin, non-protein bound thyroxine. triiodothyronine. cobalamines and folates, using an Elecsys(R) 2010 analyser. All the logistic work has been done in co-operation with the supplier of the analyser (Roche Diagnostics Espana. S.L., Barcelona). The reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. The multicentric reference limits were estimated according to the recommendations of the International Federation of Clinical Chemistry. The work done represents a model of co-operation between the in vitro diagnostic industry and clinical laboratories for the production of reference values. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 146
页数:4
相关论文
共 13 条
[1]  
BLAABJERG O, 1994, UPSALA J MED SCI, V99, P357
[2]  
Conover W, 1980, PRACTICAL NONPARAMET, P229
[3]  
FerreMasferrer M, 1997, EUR J CLIN CHEM CLIN, V35, P715
[4]   ANALYTICAL GOALS FOR THE ACCEPTANCE OF COMMON REFERENCE INTERVALS FOR LABORATORIES THROUGHOUT A GEOGRAPHICAL AREA [J].
GOWANS, EMS ;
PETERSEN, PH ;
BLAABJERG, O ;
HORDER, M .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 (08) :757-764
[5]  
HARRIS EK, 1990, CLIN CHEM, V36, P265
[6]  
*INT FED CLIN CHEM, 1987, CLIN CHIM ACTA, V170, pS33
[7]  
*INT FED CLIN CHEM, 1988, CLIN CHIM ACTA, V177, pS3
[8]  
*INT FED CLIN CHEM, 1987, CLIN CHIM ACTA, V170, pS1
[9]  
*INT FED CLIN CHEM, 1987, CLIN CHIM ACTA, V165, P111
[10]  
*INT ORG STAND, 2000, 15189 ISOFDIS