Optimal Power Flow Incorporating Frequency Security Constraint

被引:47
作者
Nga Nguyen [1 ]
Almasabi, Saleh [2 ]
Bera, Atri [3 ]
Mitra, Joydeep [3 ]
机构
[1] Univ Wyoming, Dept Elect & Comp Engn, Laramie, WY 82071 USA
[2] Najran Univ, Dept Elect Engn, Najran, Saudi Arabia
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
关键词
Equivalent regulation constant; frequency deviation; frequency security; inertia; optimal power flow (OPF); SYSTEM; STABILITY; ALGORITHM; RELIABILITY;
D O I
10.1109/TIA.2019.2938918
中图分类号
T [工业技术];
学科分类号
120111 [工业工程];
摘要
Optimal power flow (OPF) minimizes the production cost, while satisfying the constraints on the system, such as real and reactive power balance, equipment capability constraints, and voltage limits. This article presents a method of incorporating a frequency security constraint within the framework of the OPF problem. Increasing displacement of conventional generation by renewable resources that contribute little or no frequency regulation capability may necessitate the enforcement of such a constraint to meet frequency security requirements. The system frequency is required to be maintained within a safe limit, thus indicating the balance between generation and consumption. Hence, the solution for optimization of power flow should not only present a minimum cost of generation within the operating conditions, but also ensure frequency stability. In order to obtain this solution, the requirement of frequency stability is introduced as a new constraint of the power dispatch problem and is represented by the maximum frequency deviation limit. This new constraint is constructed as a nonlinear function of system inertia and the frequency regulation constant, since frequency deviation is highly sensitive to these factors. It is shown that the inclusion of this constraint causes the OPF to preferentially select higher inertia generators as necessary, to satisfy the frequency security requirement. A genetic algorithm is utilized as the optimization tool in this article. The IEEE RTS-79 test system is used to demonstrate efficacy of the proposed method.
引用
收藏
页码:6508 / 6516
页数:9
相关论文
共 41 条
[1]
Solution techniques for transient stability-constrained optimal power flow - Part I [J].
Abhyankar, Shrirang ;
Geng, Guangchao ;
Anitescu, Mihai ;
Wang, Xiaoyu ;
Dinavahi, Venkata .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (12) :3177-3185
[2]
Security-Constrained Unit Commitment With Linearized System Frequency Limit Constraints [J].
Ahmadi, Hamed ;
Ghasemi, Hassan .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (04) :1536-1545
[3]
A general-order system frequency response model incorporating load shedding: Analytic modeling and applications [J].
Aik, DLH .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (02) :709-717
[4]
Al-Maadeed SA, 2016, PROC EUR CONF INTELL, P1
[5]
A LOW-ORDER SYSTEM FREQUENCY-RESPONSE MODEL [J].
ANDERSON, PM ;
MIRHEYDAR, M .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (03) :720-729
[6]
[Anonymous], 2011, BAL FREQ CONTR
[7]
[Anonymous], 2011, 24 NERC IVG TF
[8]
[Anonymous], 2017, THESIS
[9]
[Anonymous], 2018, Proc. IEEE PES/IAS Power Africa Conf
[10]
[Anonymous], DOENETL20111473