An evaluation method of gas distribution quality in proton exchange membrane fuel cell

被引:56
作者
Chen, Huicui [1 ]
Zhao, Xin [1 ]
Qu, Bingwang [1 ]
Zhang, Tong [1 ]
Pei, Pucheng [2 ]
Li, Congxin [3 ]
机构
[1] Tongji Univ, Sch Automot Studies, Shanghai 201804, Peoples R China
[2] Tsinghua Univ, State Key Lab Automot Safety & Energy, Beijing 100084, Peoples R China
[3] Beijing Automot Res Ctr Co Ltd, Beijing 101300, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane fuel cell; Dynamic loading; Gas distribution quality evaluation; Gas starvation diagnose; ACCELERATED DEGRADATION; PTFE/NAFION MEMBRANE; TRANSIENT-RESPONSE; CARBON CORROSION; DYNAMIC-BEHAVIOR; DIFFUSION LAYER; PEMFC; REVERSAL; PERFORMANCE; STOICHIOMETRY;
D O I
10.1016/j.apenergy.2018.09.031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
The proton exchange membrane fuel cell is considered to be the best alternative to next generation power system due to its high efficiency without emission. It has been found that the lack of gas supply due to frequent load change and start-stop is a very crucial factor in fuel cell life decay and restricts its commercialization. Gas starvation is the state in which the reaction gas of proton exchange membrane fuel cell operates at a substoichiometric level. The diagnosis of local gas starvation without additional expensive and intrusive sensors is still a tough problem not to be solved. In this paper, the area of gas starvation is calculated to evaluate the degree of gas starvation. A novel statistical analysis based method is applied as the index to measure the uniformity of the reaction gas concentration directly on the surface of electrode. The distribution quality of reaction gas under both steady-state and dynamic conditions was evaluated by simulating different operating conditions through the simulation model established. A suitable working area of the fuel cell under steady state is proposed to achieve more stable cell performance under load change conditions. The distribution quality of reaction gas concentration on the whole electrode surface under dynamic condition is evaluated to identify the specific areas where gas starvation is likely to occur. The results of this study will provide the basis for the optimal control and structural design of the fuel cell against dynamic gas starvation, and contribute to the long-life study of proton exchange membrane fuel cells.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 41 条
[1]
Local potential evolutions during proton exchange membrane fuel cell operation with dead-ended anode - Part I: Impact of water diffusion and nitrogen crossover [J].
Abbou, S. ;
Dillet, J. ;
Maranzana, G. ;
Didierjean, S. ;
Lottin, O. .
JOURNAL OF POWER SOURCES, 2017, 340 :337-346
[2]
Numerical and experimental investigation of cascade type serpentine flow field of reactant gases for improving performance of PEM fuel cell [J].
Alizadeh, E. ;
Rahimi-Esbo, M. ;
Rahgoshay, S. M. ;
Saadat, S. H. M. ;
Khorshidian, M. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (21) :14708-14724
[3]
Bodner M, 2016, FUEL CELLS
[4]
Carbon corrosion and performance degradation mechanism in a proton exchange membrane fuel cell with dead-ended anode and cathode [J].
Chen, Ben ;
Wang, Jun ;
Yang, Tianqi ;
Cai, Yonghua ;
Zhang, Caizhi ;
Chan, Siew Hwa ;
Yu, Yi ;
Tu, Zhengkai .
ENERGY, 2016, 106 :54-62
[5]
Mitigation studies of carbon corrosion by optimizing the opening size of the cathode outlet in a proton exchange membrane fuel cell with dead-ended anode [J].
Chen, Ben ;
Wang, Jun ;
Yang, Tianqi ;
Cai, Yonghua ;
Pan, Mu ;
Tu, Zhengkai ;
Zhang, Caizhi ;
Chan, Siew Hwa ;
Yu, Yi .
ENERGY CONVERSION AND MANAGEMENT, 2016, 119 :60-66
[6]
Chen H., 2015, DYNAMIC RESPONSE ANA
[7]
Chen Huicui, 2014, J TSINGHUA U SCI TEC, V10, P1298
[8]
Transient response of a unit proton-exchange membrane fuel cell under various operating conditions [J].
Cho, Junhyun ;
Kim, Han-Sang ;
Min, Kyoungdoug .
JOURNAL OF POWER SOURCES, 2008, 185 (01) :118-128
[9]
PEFC Stack Operating in Anodic Dead End Mode [J].
Dumercy, L. ;
Pera, M-C ;
Glises, R. ;
Hissel, D. ;
Hamandi, S. ;
Badin, F. ;
Kauffmann, J-M .
FUEL CELLS, 2004, 4 (04) :352-357
[10]
Effect of operating parameters on the transient performance of a polymer electrolyte membrane fuel cell stack with a dead-end anode [J].
Gomez, Alberto ;
Raj, Abhishek ;
Sasmito, Agus P. ;
Shamim, Tariq .
APPLIED ENERGY, 2014, 130 :692-701