Computerized ultrasound B-scan characterization of breast nodules

被引:54
作者
Lefebvre, F
Meunier, M
Thibault, F
Laugier, P
Berger, G
机构
[1] Lab Imagerie Parametr, CNRS, UMR 7623, Paris, France
[2] Inst Curie, Serv Radiodiagnost, Paris, France
关键词
ultrasound imaging; tissue characterization; breast cancer; texture analysis;
D O I
10.1016/S0301-5629(00)00302-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The ability of computerized parameters to discriminate benign from malignant breast nodules from digitized ultrasonic acquisitions has been assessed. The images of 75 lesions, including 19 lesions proved to be malignant at histology and 56 found to be benign, were digitized and characterized by morphometric and texture parameters. The texture parameters, derived from first-order statistics, run-length matrices and co-occurrence matrices, were computed in the entire lesion and in a ring-shape region surrounding the contour of the lesion. The strongest features were found to be issued from the second region. Further investigations confirmed that the discriminant information was contained in the external part of the lesion and, to a lesser extent, in the neighboring tissue. A linear discriminant analysis using three features yielded a sensitivity of 94.7% for a specificity of 80.4% and the "leave-one-out" technique confirmed the results. Comparison with the classifications given by radiologists let us assume that information revealed by texture features is able to help the physician in reducing the number of unnecessary biopsies. (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1421 / 1428
页数:8
相关论文
共 28 条
[1]   TEXTURE ANALYSIS OF ULTRASONIC IMAGES OF THE PROSTATE BY MEANS OF COOCCURRENCE MATRICES [J].
BASSET, O ;
SUN, Z ;
MESTAS, JL ;
GIMENEZ, G .
ULTRASONIC IMAGING, 1993, 15 (03) :218-237
[2]  
BOUDINET M, 1994, EUR J ULTRASOUND, V1, P251
[3]  
Breiman L., 1984, BIOMETRICS, DOI DOI 10.2307/2530946
[4]   USE OF GRAY VALUE DISTRIBUTION OF RUN LENGTHS FOR TEXTURE ANALYSIS [J].
CHU, A ;
SEHGAL, CM ;
GREENLEAF, JF .
PATTERN RECOGNITION LETTERS, 1990, 11 (06) :415-419
[5]   QUANTITATIVE ECHOCARDIOGRAPHIC IMAGE TEXTURE - NORMAL CONTRACTION-RELATED VARIABILITY [J].
COLLINS, SM ;
SKORTON, DJ ;
PRASAD, NV ;
OLSHANSKY, B ;
BEAN, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (04) :185-192
[6]   CLASSIFICATION OF ULTRASONIC IMAGE TEXTURE BY STATISTICAL DISCRIMINANT-ANALYSIS AND NEURAL NETWORKS [J].
DAPONTE, JS ;
SHERMAN, P .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (01) :3-9
[7]   IMAGE CHARACTERIZATIONS BASED ON JOINT GRAY LEVEL RUN LENGTH DISTRIBUTIONS [J].
DASARATHY, BV ;
HOLDER, EB .
PATTERN RECOGNITION LETTERS, 1991, 12 (08) :497-502
[8]   A GENERAL MAXIMUM LIKELIHOOD DISCRIMINANT [J].
DAY, NE ;
KERRIDGE, DF .
BIOMETRICS, 1967, 23 (02) :313-&
[9]  
Farabet O., 1987, NOTE TISSUE CHARACTE, P1
[10]   CONSIDERATIONS OF SAMPLE AND FEATURE SIZE [J].
FOLEY, DH .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1972, 18 (05) :618-+