Increased-resolution OCT thickness mapping of the human macula: A statistically based registration

被引:9
作者
Bernardes, Rui [1 ,2 ]
Santos, Torcato [1 ]
Cunha-Vaz, Jose [1 ,3 ]
机构
[1] AIBILI CNTM, Coimbra, Portugal
[2] Univ Coimbra, Inst Biofis & Biomatemat, Fac Med, IBILI, Coimbra, Portugal
[3] Univ Coimbra, Fac Med, IBILI, Ctr Oftalmol, Coimbra, Portugal
关键词
D O I
10.1167/iovs.07-0467
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To describe the development of a technique that enhances spatial resolution of retinal thickness maps of the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA). A retinal thickness atlas (RT-atlas) template was calculated, and a macular coordinate system was established, to pursue this objective. METHODS. The RT-atlas was developed from principal component analysis of retinal thickness analyzer (RTA) maps acquired from healthy volunteers. The Stratus OCT radial thickness measurements were registered on the RT-atlas, from which an improved macular thickness map was calculated. Thereafter, Stratus OCT circular scans were registered on the previously calculated map to enhance spatial resolution. RESULTS. The developed technique was applied to Stratus OCT thickness data from healthy volunteers and from patients with diabetic retinopathy (DR) or age-related macular degeneration (AMD). Results showed that for normal, or close to normal, macular thickness maps from healthy volunteers and patients with DR, this technique can be an important aid in determining retinal thickness. Efforts are under way to improve the registration of retinal thickness data in patients with AMD. CONCLUSIONS. The developed technique enhances the evaluation of data acquired by the Stratus OCT, helping the detection of early retinal thickness abnormalities. Moreover, a normative database of retinal thickness measurements gained from this technique, as referenced to the macular coordinate system, can be created without errors induced by missed fixation and eye tilt.
引用
收藏
页码:2046 / 2052
页数:7
相关论文
共 27 条
[1]  
Bouma B.E., 2002, Handbook of Optical Coherence Tomography
[2]  
Ciulla T. A., 2003, RETINA OPTIC NERVE I
[3]   Diabetic retinopathy and diabetic macular edema - Pathophysiology, screening, and novel therapies [J].
Ciulla, TA ;
Amador, AG ;
Zinman, B .
DIABETES CARE, 2003, 26 (09) :2653-2664
[4]  
Costa L.d. F., 2001, SHAPE ANAL CLASSIFIC
[5]  
CUNHAVAZ J, 2002, CONT OPHTHALMOL, V1, P1
[6]   A spatially unbiased atlas template of the human cerebellum [J].
Diedrichsen, Jorn .
NEUROIMAGE, 2006, 33 (01) :127-138
[7]   Clinical assessment of the macula by retinal topography and thickness mapping [J].
Gieser, JP ;
Rusin, MM ;
Mori, M ;
Blair, NP ;
Shahidi, M .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (05) :648-660
[8]   Topography of diabetic macular edema with optical coherence tomography [J].
Hee, MR ;
Puliafito, CA ;
Duker, JS ;
Reichel, E ;
Coker, JG ;
Wilkins, JR ;
Schuman, JS ;
Swanson, EA ;
Fujimoto, JG .
OPHTHALMOLOGY, 1998, 105 (02) :360-370
[9]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[10]   Statistical shape model generation using nonrigid deformation of a template mesh [J].
Heitz, G ;
Rohlfing, T ;
Maurer, CR .
Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 :1411-1421