Estimation of end-expiratory lung volume variations by optoelectronic plethysmography

被引:35
作者
Dellacà, RL
Aliverti, A
Pelosi, P
Carlesso, E
Chiumello, D
Pedotti, A
Gattinoni, L
机构
[1] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
[2] Politecn Milan, Fond Don Gnocchi IRCCS, Ctr Bioingn, I-20133 Milan, Italy
[3] Univ Insubria, Dipartimento Sci Clin & Biol, Varese, Italy
[4] Univ Milan, Ist Anestesia & Rianimaz, Milan, Italy
[5] Osped Maggiore, IRCCS, Serv Anestesia & Rianimaz, Milan, Italy
关键词
end-expiratory lung volume; optoelectronic plethysmography; acute respiratory failure; helium dilution technique;
D O I
10.1097/00003246-200109000-00026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To test the capability of optoelectronic plethysmography (OEP) to monitor positive end-expiratory pressure (PEEP)induced changes of end-expiratory lung volume (EELV) changes in mechanically ventilated paralyzed patients. Design: Laboratory and clinical investigation. Setting: Intensive care unit of the Ospedale Maggiore Policlinico di Milano. Patients. A total of eight patients with respiratory failure of various degrees, sedated and paralyzed. Interventions. PEEP variations (+/-5 cm H2O) relative to the baseline PEEP of 10 cm H2O. Measurements and Main Results: In the model protocol, we tested the reproducibility of the OEP by repeating volume measurements of a plastic torso model over a 21-hr period, every 30 mins. The variations of OEP measurements of the torso model (9337 mL value) were encountered in a range of 16 mL (SD = 4 mL). In the patient protocol, we measured the end-expiratory volume of the chest wall (EEVCW) breath-by-breath by OEP before, during, and after the PEEP increase/decrease and we compared its variations with the corresponding variations of EELV measured by helium dilution technique. The regression line between EELV changes measured by helium and EEVCW changes measured by OEP resulted very close to the identity line (slope 1.06, intercept -0.02 L, r(2) = 0.89) and their difference was not related to their absolute magnitude. After PEEP increase, the new steady state of EEVCW was reached approximately in 15 breaths; and, after PEEP decrease, in 3-4 breaths. The slow increase in EEVCW was mainly because of the abdominal compartment. Conclusion: OEP measurements of EEVCW accurately reflect the changes of EELV. Furthermore, OEP allows a continuous compartmental analysis, even during unsteady conditions.
引用
收藏
页码:1807 / 1811
页数:5
相关论文
共 22 条
[1]   Optoelectronic plethysmography in intensive care patients [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Pedotti, A ;
Gattinoni, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (05) :1546-1552
[2]   Human respiratory muscle actions and control during exercise [J].
Aliverti, A ;
Cala, SJ ;
Duranti, R ;
Ferrigno, G ;
Kenyon, CM ;
Pedotti, A ;
Scano, G ;
Sliwinski, P ;
Macklem, PT ;
Yan, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (04) :1256-1269
[3]   Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Gattinoni, L ;
Pedotti, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (01) :60-70
[4]  
ALIVERTI A, 2000, EUR RESP J S31, V16, pS198
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Chest wall and lung volume estimation by optical reflectance motion analysis [J].
Cala, SJ ;
Kenyon, CM ;
Ferrigno, G ;
Carnevali, P ;
Aliverti, A ;
Pedotti, A ;
Macklem, PT ;
Rochester, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2680-2689
[7]   PERIOPERATIVE CHANGES IN FUNCTIONAL RESIDUAL CAPACITY IN MORBIDLY OBESE PATIENTS [J].
DAMIA, G ;
MASCHERONI, D ;
CROCI, M ;
TARENZI, L .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (05) :574-578
[8]   VENTILATION WITH END-EXPIRATORY PRESSURE IN ACUTE LUNG-DISEASE [J].
FALKE, KJ ;
LAVER, MB ;
KUMAR, A ;
PONTOPPI.H ;
LEITH, DE ;
GEFFIN, B .
JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (09) :2315-+
[9]  
Fretschner R, 1996, INTENS CARE MED, V22, P1328
[10]   EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE ON REGIONAL DISTRIBUTION OF TIDAL VOLUME AND RECRUITMENT IN ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
GATTINONI, L ;
PELOSI, P ;
CROTTI, S ;
VALENZA, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) :1807-1814