Collagen covalently immobilized onto plastic surfaces simplifies measurement of von Willebrand factor-collagen binding activity

被引:21
作者
Fischer, BE
Thomas, KB
Dorner, F
机构
[1] BYK Gulden Lomberg GmbH, Dept FMF, D-78467 Konstanz, Germany
[2] Immuno AG, Ctr Biomed Res, A-2304 Orth Donau, Austria
关键词
collagen; ELISA; carbohydrate modification; multimers; ristocetin cofactor activity; von Willebrand factor; von Willebrand disease; collagen binding activity;
D O I
10.1007/s002770050381
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Human collagen type III was immobilized covalently via activated carbohydrate moieties onto hydrazine-treated microtiter plates which could be used to measure von Willebrand factor (vWF) collagen binding activity (vWF:CBA) in an ELISA. Such plates were simple to prepare and remained stable at 4 degrees C and -20 degrees C for at least 2 months. Samples analyzed by this system included (a) normal human vWF fractionated according to the degree of multimerization, (b) normal citrated and EDTA plasma and corresponding serum, and (c) plasma from patients with von Willebrand disease (vWD) types 1 and 2. When related to the concentration of vWF antigen (vWF:Ag), proportionally low levels of vWF:CBA were found for samples lacking the high-molecular-weight multimers, while higher values were obtained for samples containing these multimers. The ratio of vWF:CBA/vWF:Ag sensitively reflected the functional and structural intactness of the vWF molecules for all analyzed samples. Monoclonal antibody directed to the region within the A1 domain of vWF which interacts with the glycoprotein Ib completely inhibited the vWF ristocetin cofactor (vWF:RistCof), while vWF:CBA was not affected. Thus vWF:CBA and vWF:RistCof clearly represent separate, noninterchangeable functional parameters of vWF. In conclusion, our results indicate that the newly described method for the immobilization of collagen onto microtiter plates is suitable for the determination of vWF:CBA. In conjunction with vWF:Ag and the calculated ratio of vWF:CBA/vWF:Ag, this method simplifies the detection and classification of patients with vWD and assists in quality control during the purification of normal vWF.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 26 条
[1]   BINDING AND COVALENT CROSS-LINKING OF PURIFIED VONWILLEBRAND-FACTOR TO NATIVE MONOMERIC COLLAGEN [J].
BOCKENSTEDT, P ;
MCDONAGH, J ;
HANDIN, RI .
JOURNAL OF CLINICAL INVESTIGATION, 1986, 78 (02) :551-556
[2]   AN ELISA TEST FOR THE BINDING OF VONWILLEBRAND ANTIGEN TO COLLAGEN [J].
BROWN, JE ;
BOSAK, JO .
THROMBOSIS RESEARCH, 1986, 43 (03) :303-311
[3]   O-LINKED CARBOHYDRATE OF RECOMBINANT VONWILLEBRAND-FACTOR INFLUENCES RISTOCETIN-INDUCED BINDING TO PLATELET GLYCOPROTEIN-1B [J].
CAREW, JA ;
QUINN, SM ;
STODDART, JH ;
LYNCH, DC .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 90 (06) :2258-2267
[4]   VON WILLEBRANDS DISEASE - USE OF COLLAGEN-BINDING ASSAY PROVIDES POTENTIAL IMPROVEMENT TO LABORATORY MONITORING OF DESMOPRESSIN (DDAVP) THERAPY [J].
FAVALORO, EJ ;
DEAN, M ;
GRISPO, L ;
EXNER, T ;
KOUTTS, J .
AMERICAN JOURNAL OF HEMATOLOGY, 1994, 45 (03) :205-211
[5]   DEVELOPMENT OF A SIMPLE COLLAGEN BASED ELISA ASSAY AIDS IN THE DIAGNOSIS OF, AND PERMITS SENSITIVE DISCRIMINATION BETWEEN TYPE-I AND TYPE-II, VONWILLEBRANDS DISEASE [J].
FAVALORO, EJ ;
GRISPO, L ;
EXNER, T ;
KOUTTS, J .
BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (02) :285-291
[6]   STRUCTURAL-ANALYSIS OF RECOMBINANT VON-WILLEBRAND-FACTOR - IDENTIFICATION OF HETERO-DIMERS AND HOMO-DIMERS [J].
FISCHER, B ;
MITTERER, A ;
SCHLOKAT, U ;
DENBOUWMEESTER, R ;
DORNER, F .
FEBS LETTERS, 1994, 351 (03) :345-348
[7]   STRUCTURAL-ANALYSIS OF RECOMBINANT VON-WILLEBRAND-FACTOR PRODUCED AT INDUSTRIAL-SCALE FERMENTATION OF TRANSFORMED CHO CELLS CO-EXPRESSING RECOMBINANT FURIN [J].
FISCHER, BE ;
SCHLOKAT, U ;
MITTERER, A ;
REITER, M ;
MUNDT, W ;
TURECEK, PL ;
SCHWARZ, HP ;
DORNER, F .
FEBS LETTERS, 1995, 375 (03) :259-262
[8]   Effect of multimerization of human and recombinant von Willebrand factor on platelet aggregation, binding to collagen and binding of coagulation factor VIII [J].
Fischer, BE ;
Kramer, G ;
Mitterer, A ;
Grillberger, L ;
Reiter, M ;
Mundt, W ;
Dorner, F ;
Eibl, J .
THROMBOSIS RESEARCH, 1996, 84 (01) :55-66
[9]   von Willebrand factor: molecular size and functional activity [J].
Furlan, M .
ANNALS OF HEMATOLOGY, 1996, 72 (06) :341-348
[10]   AN IMMUNORADIOMETRIC ASSAY FOR HUMAN FACTOR-VIII/VONWILLEBRAND FACTOR (VIII-VWF) USING A MONOCLONAL-ANTIBODY THAT DEFINES A FUNCTIONAL EPITOPE [J].
GOODALL, AH ;
JARVIS, J ;
CHAND, S ;
RAWLINGS, E ;
OBRIEN, DP ;
MCGRAW, A ;
HUTTON, R ;
TUDDENHAM, EGD .
BRITISH JOURNAL OF HAEMATOLOGY, 1985, 59 (04) :565-577