Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters

被引:30
作者
Almeida, P
Bendriem, B
de Dreuille, O
Peltier, A
Perrot, C
Brulon, V
机构
[1] CEA, Serv Hosp Frederic Joliot, Dept Rech Med, Direct Sci Vivant, F-91406 Orsay, France
[2] Hop Val de Grace, Nucl Med Serv, Paris, France
[3] CEA, Serv Radioprotect Installat, Serv Protect Rayonnements, Unite Gest Secur Protect, Saclay, France
关键词
positron emission tomography; single-photon emission tomography; transmission measurements; radiation dose; thermoluminescent dosimeters;
D O I
10.1007/s002590050320
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantification in positron emission tomogrpahy (PET) and single photon emission tomographic (SPET) relies on attenuation correction which is generally obtained with an additional transmission measurement. Therefore, the evaluation of the radiation doses received by patients needs to include the contribution of transmission procedures in SPET (SPET-TM) and PET (PET-TM). In this work we have measured these doses for both PET-TM and SPET-TM. PET-TM was performed on an ECAT EXACT HR+ (CTI/Siemens) equipped with three rod sources of germanium-68 (380 MBq total) and extended septa. SPET-TM was performed on a DST (SMV) equipped with two collimated line sources of gadolinium-153 (4 GBq total). Two anthropomorphic phantoms representing a human head and a human torso, were used to estimate the doses absorbed in typical cardiac and brain transmission studies. Measurements were made with thermoluminescent dosimeters (TLDs, consisting of lithium fluoride) having characteristics suitable for dosimetry investigations in nuclear medicine. Sets of TLDs were placed inside small plastic bags and then attached to different organs of the phantoms (at least two TLDs were assigned to a given organ). Before and after irradiation the TLDs were placed in a 2.5-cm-thick lead container to prevent exposure from occasional sources. Ambient radiation was monitored and taken into account in calculations. Transmission scans were performed for more than 12 h in each case to decrease statistical noise fluctuations. The doses absorbed by each organ were calculated by averaging the values obtained for each corresponding TLD. These values were used to evaluate the effective dose (ED) following guidelines described in ICRP report number 60. The estimated ED values for cardiac acquisitions were 7.7x10(4)+/-0.4x10(-4) mSv/MBq . h and 1.9x10(-6)+/-0.4x10(-6) mSv/MBq . h for PET-TM and SPET-TM. respectively. For brain scans, the values of ED were calculated as 2.7x10(-4)+/-0.2x10(-4) mSv/MBq . h for PET-TM and 5.2x10(-7)+/-2.3x10(-7) mSv/MBq . h for SPET-TM. In our institution, PET-TM is usually performed for 15 min prior to emission. SPET-TM is performed simultaneously with emission and usually lasts 30 and 15 min for brain and cardiac acquisitions respectively. Under these conditions ED values, estimated for typical source activities at delivery time (22000 MBq in SPET and 555 MBq for PET), were 1.1x10(-1)+/-0.1x10(-1) mSv and 1.1x10(-2)+/-0.2x10(-2) mSv for cardiac PET-TM and SPET-TM respectively. For brain acquisitions, the ED values obtained under the same conditions were 3.7x10(-2)+/-0.3x10(-2) mSv and 5.8x10(-3)+/-2.6x10(-3) mSv for PET-TM and SPET-TM respectively. These measurements show that the dose received by a patient during a transmission scan adds little to the typical dose received in a routine nuclear medicine procedure. Radiation dose, therefore, does not represent a limit to the generalised use of transmission measurements in clinical SPET or PET.
引用
收藏
页码:1435 / 1441
页数:7
相关论文
共 20 条
  • [1] [Anonymous], 1989, TISS SUBST RAD DOS M
  • [2] [Anonymous], [No title captured]
  • [3] Optimization and deconvolution of lithium fluoride TLD-100 in diagnostic radiology
    Burke, K
    Sutton, D
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 261 - 271
  • [4] PERFORMANCE-CHARACTERISTICS OF TRANSMISSION IMAGING USING A UNIFORM SHEET SOURCE WITH PARALLEL-HOLE COLLIMATION
    CAO, ZJ
    TSUI, BMW
    [J]. MEDICAL PHYSICS, 1992, 19 (05) : 1205 - 1212
  • [5] Bone equivalent liquid solution to assess accuracy of transmission measurements in SPECT and PET
    deDreuille, O
    Strijckmans, V
    Almeida, P
    Loch, C
    Bendriem, B
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1186 - 1190
  • [6] Hashimoto J, 1997, J NUCL MED, V38, P157
  • [7] HOLM S, 1996, EUR J NUCL MED, V23, P1121
  • [8] THE USE OF THE EFFECTIVE DOSE EQUIVALENT, HE, FOR TC-99M LABELED RADIOPHARMACEUTICALS
    HUDA, W
    SANDISON, GA
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (04): : 174 - 179
  • [9] KEMP BJ, 1995, J NUCL MED, V36, P328
  • [10] Kluge R, 1997, EUR J NUCL MED, V24, P1107