Transcutaneous assessment of renal function in conscious rats with a device for measuring FITC-sinistrin disappearance curves

被引:116
作者
Schock-Kusch, Daniel [1 ,2 ,3 ]
Xie, Qing [1 ,2 ,3 ]
Shulhevich, Yury [1 ,2 ,3 ]
Hesser, Juergen [2 ,3 ]
Stsepankou, Dzmitry
Sadick, Maliha [4 ]
Koenig, Stefan [5 ]
Hoecklin, Friederike [6 ]
Pill, Johannes [1 ]
Gretz, Norbert [1 ,2 ,3 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Med Res Ctr, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Inst Med Technol, D-68167 Mannheim, Germany
[3] Univ Appl Sci, Mannheim, Germany
[4] Heidelberg Univ, Med Fac Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[5] Freudenberg Forsch Dienste KG, Weinheim, Germany
[6] Freudenberg MekTek Europa GmbH, Weinheim, Germany
关键词
FITC-sinistrin; fluorometric; GFR; kidney function; transcutaneous; GLOMERULAR-FILTRATION-RATE; FLUORESCEIN-LABELED SINISTRIN; MARKER; AGREEMENT;
D O I
10.1038/ki.2011.31
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Determination of the urinary or plasma clearance of exogenous renal markers, such as inulin or iohexol, is considered to be the gold standard for glomerular filtration rate (GFR) measurement. Here, we describe a technique allowing determination of renal function based on transcutaneously measured elimination kinetics of fluorescein isothiocyanate (FITC)-sinistrin, the FITC-labeled active pharmaceutical ingredient of a commercially available marker of GFR. A low cost device transcutaneously excites FITC-sinistrin at 480 nm and detects the emitted light through the skin at 520nm. A radio-frequency transmission allows remote monitoring and real-time analysis of FITC-sinistrin excretion as a marker of renal function. Due to miniaturization, the whole device fits on the back of freely moving rats, and requires neither blood sampling nor laboratory assays. As proof of principle, comparative measurements of transcutaneous and plasma elimination kinetics of FITC-sinistrin were compared in freely moving healthy rats, rats showing reduced kidney function due to unilateral nephrectomy and PKD/Mhm rats with cystic kidney disease. Results show highly comparable elimination half-lives and GFR values in all animal groups. Bland-Altman analysis of enzymatically compared with transcutaneously measured GFR found a mean difference (bias) of 0.01 and a -0.30 to 0.33 ml/min per 100 g body weight with 95% limit of agreement. Thus, with this device, renal function can be reliably measured in freely moving rats eliminating the need for and influence of anesthesia on renal function. Kidney International (2011) 79, 1254-1258; doi:10.1038/ki.2011.31; published online 2 March 2011
引用
收藏
页码:1254 / 1258
页数:5
相关论文
共 22 条
[1]  
Bird NJ, 2003, J NUCL MED, V44, P1037
[2]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements:: A phase I trial [J].
Boss, Andreas ;
Martirosian, Petros ;
Gehrmann, Michael ;
Artunc, Ferruh ;
Risler, Teut ;
Oesingmann, Niels ;
Claussen, Claus D. ;
Schick, Fritz ;
Kueper, Klaus ;
Schlemmer, Heinz-Peter .
RADIOLOGY, 2007, 242 (03) :783-790
[5]   Missense mutation in sterile α motif of novel protein SamCystin is associated with polycystic kidney disease in (cy/+) rat [J].
Brown, JH ;
Bihoreau, MT ;
Hoffmann, S ;
Kränzlin, B ;
Tychinskaya, I ;
Obermüller, N ;
Podlich, D ;
Boehn, SN ;
Kaisaki, PJ ;
Megel, N ;
Danoy, P ;
Copley, RR ;
Broxholme, J ;
Witzgall, R ;
Lathrop, M ;
Gretz, N ;
Gauguier, D .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2005, 16 (12) :3517-3526
[6]   Fluorescence-enhanced europium-diethylenetriaminepentaacetic (DTPA)-monoamide complexes for the assessment of renal function [J].
Chinen, Lori K. ;
Galen, Karen P. ;
Kuan, K. T. ;
Dyszlewski, Mary E. ;
Ozaki, Hiroaki ;
Sawai, Hiroaki ;
Pandurangi, Raghootama S. ;
Jacobs, Frederick G. ;
Dorshow, Richard B. ;
Rajagopalan, Raghavan .
JOURNAL OF MEDICINAL CHEMISTRY, 2008, 51 (04) :957-962
[7]  
COLSON P, 1992, ANESTH ANALG, V74, P481
[8]   NONINVASIVE FLUORESCENCE DETECTION OF HEPATIC AND RENAL FUNCTION [J].
Dorshow, Richard B. ;
Bugaj, Joseph E. ;
Burleigh, B. Daniel ;
Duncan, James R. ;
Johnson, Michael A. ;
Jones, William B. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) :340-345
[9]   Influence of three anesthetic protocols on glomerular filtration rate in dogs [J].
Fusellier, Marion ;
Desfontis, Jean-Claude ;
Madec, Stephane ;
Gautier, Freddy ;
Debailleul, Michelle ;
Gogny, Marc .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2007, 68 (08) :807-811
[10]   Calculation of glomerular filtration rate in conscious rats by the use of a bolus injection of iodixanol and a single blood sample [J].
Katayama, Rieko ;
Yamaguchi, Nami ;
Yamashita, Tetsuro ;
Watanabe, Shuji ;
Satoh, Hiroshi ;
Yamagishi, Norio ;
Furuhama, Kazuhisa .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2010, 61 (01) :59-64