Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography

被引:69
作者
Hammer, FD [1 ]
Goffette, PP
Malaise, J
Mathurin, P
机构
[1] Univ Catholique Louvain, St Luc Univ Hosp, Dept Radiol, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, St Luc Univ Hosp, Dept Kidney Transplantat, B-1200 Brussels, Belgium
关键词
digital subtraction angiography; gadolinium; MR imaging; contrast media; kidney failure;
D O I
10.1007/s003300050643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate gadolinium diethylenetriaminepenta-acetic acid (Gd-DTPA) as an alternative contrast agent for digital subtraction angiography (DSA) in patients with renal insufficiency or previous anaphylactic reaction to iodinated contrast agents. We performed 34 DSAs in 31 patients by use of the commercially available 0.5-M Gd-DTPA solution (Magnevist, Schering, Berlin, Germany). The contrast material was power- or hand-injected at the same rate as iodinated contrast material, without exceeding a total amount of 0.4 mmol/kg body weight. In 18 studies Gd-DTPA was the sole contrast agent. In 9 cases gadolinium injections were combined with carbon dioxide. Restricted non-ionic contrast medium injections were administered to complete the examinations in 7 cases and for comparative purposes in 1 case. Cerebral and carotid arteries, one superior limb, abdominal aorta, renal arteries? renal transplants, iliac arteries and inferior limbs were imaged, and ten endovascular interventional procedures, including three transjugular intrahepatic percutaneous stent shunts, were per farmed. No side effects were observed. Diagnostic angiographic images were obtained in all cases except in 5 of the 8 distal run-off studies. Gadolinium-based contrast can produce clinically useful angiograms in patients with a contra-indication to iodine who must undergo angiography.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 27 条
  • [1] BITTNER CA, 1997, J VASC INTERV RADI S, V8, P178
  • [2] GD-DTPA AS A CONTRAST AGENT IN CT
    BLOEM, JL
    WONDERGEM, J
    [J]. RADIOLOGY, 1989, 171 (02) : 578 - 579
  • [3] EXPERIMENTAL AND THEORETICAL X-RAY-IMAGING PERFORMANCE COMPARISON OF IODINE AND LANTHANIDE CONTRAST AGENTS
    CARDINAL, HN
    HOLDSWORTH, DW
    DRANGOVA, M
    HOBBS, BB
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 15 - 31
  • [4] Fobbe F, 1996, EUR RADIOL, V6, P224
  • [5] SAFETY ASSESSMENT OF GADOPENTETATE DIMEGLUMINE IN UNITED-STATES CLINICAL-TRIALS
    GOLDSTEIN, HA
    KASHANIAN, FK
    BLUMETTI, RF
    HOLYOAK, WL
    HUGO, FP
    BLUMENFIELD, DM
    [J]. RADIOLOGY, 1990, 174 (01) : 17 - 23
  • [6] ACUTE RENAL DYSFUNCTION IN HIGH-RISK PATIENTS AFTER ANGIOGRAPHY - COMPARISON OF IONIC AND NONIONIC CONTRAST-MEDIA
    GOMES, AS
    LOIS, JF
    BAKER, JD
    MCGLADE, CT
    BUNNELL, DH
    HARTZMAN, S
    [J]. RADIOLOGY, 1989, 170 (01) : 65 - 68
  • [7] RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE
    HAUSTEIN, J
    NIENDORF, HP
    KRESTIN, G
    LOUTON, T
    SCHUHMANNGIAMPIERI, G
    CLAUSS, W
    JUNGE, W
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (02) : 153 - 156
  • [8] CO2 DIGITAL ANGIOGRAPHY - A SAFER CONTRAST AGENT FOR RENAL VASCULAR IMAGING
    HAWKINS, IF
    WILCOX, CS
    KERNS, SR
    SABATELLI, FW
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) : 685 - 694
  • [9] KAUFMAN JA, 1996, RADIOLOGY, V198, P578
  • [10] GADOPENTETATE DIMEGLUMINE AS AN ALTERNATIVE CONTRAST MATERIAL FOR USE IN ANGIOGRAPHY
    KINNO, Y
    ODAGIRI, K
    ANDOH, K
    ITOH, Y
    TARAO, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1293 - 1294