Assessment of oesophageal motor function using combined perfusion manometry and multi-channel intraluminal impedance measurement in normal subjects

被引:49
作者
Nguyen, NQ
Rigda, R
Tippett, M
Conchillo, J
Smout, AJPM
Holloway, RH
机构
[1] Royal Adelaide Hosp, Dept Gastroenterol Hepatol & Gen Med, Adelaide, SA 5000, Australia
[2] Univ Med Ctr, Dept Gastroenterol, Utrecht, Netherlands
关键词
impedance; motility; oesophagus; peristalsis;
D O I
10.1111/j.1365-2982.2005.00646.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Multichannel intraluminal impedance (MII) is being used increasingly to assess oesophageal bolus clearance. However, there is no good standardization of the impedance parameters that define 'effective bolus clearance'. The aim of this study was to define these important impedance parameters and to determine their normal values, Concurrent perfusion manometry and MII were performed in 42 healthy volunteers. Ten, 5-mL liquid (saline) boluses and then, 10 x 5-mL low impedance viscous boluses were tested in each subject in the right-lateral position. Normal values for bolus presence time (BPT) at each site and total bolus transit time (TBTT) were determined from either 'normal' peristaltic responses (amplitude >= 30 mmHg in distal oesophagus) or 'super-normal' peristaltic responses (amplitudes >= 50 mmHg at all sites). The relationship between BPT and TBTT within a response and per-individual performance was determined. A total of 840 swallows of liquids and viscous responses were analysed. BPT and TBTT of viscous swallows were longer than those for liquids. Non-peristaltic responses were significantly more likely not to clear a viscous than a liquid bolus. Within a response, the number of sites with prolonged BPT strongly predicted the incidence of prolonged TBTT. Using impedance criteria, normal oesophageal bolus clearance is defined when an individual completely clears at least 70% of liquid responses and at least 60% of viscous responses. This study provides normal values for impedance measurement of bolus clearance when combined with perfusion manometry. These values will allow standardization of impedance application in oesophageal function testing, in both research and clinical setting.
引用
收藏
页码:458 / 465
页数:8
相关论文
共 20 条
  • [1] [Anonymous], 1991, J GASTROINTEST MOTIL, V3, P151, DOI DOI 10.1111/J.1365-2982.1991.TB00061.X
  • [2] PHARYNGEAL PUMP AND ESOPHAGEAL TRANSIT
    BUTHPITIYA, AG
    STROUD, D
    RUSSELL, COH
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1987, 32 (11) : 1244 - 1248
  • [3] ESOPHAGEAL FUNCTION IN HUMANS - EFFECTS OF BOLUS CONSISTENCY AND TEMPERATURE
    DOOLEY, CP
    DILORENZO, C
    VALENZUELA, JE
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1990, 35 (02) : 167 - 172
  • [4] EFFECTS OF ALTERATIONS IN BOLUS VISCOSITY ON ESOPHAGEAL PERISTALSIS IN HUMANS
    DOOLEY, CP
    SCHLOSSMACHER, B
    VALENZUELA, JE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (01): : G8 - G11
  • [5] MEASURING ESOPHAGEAL MOTILITY WITH A NEW INTRALUMINAL IMPEDANCE DEVICE - FIRST CLINICAL-RESULTS IN REFLUX PATIENTS
    FASS, J
    SILNY, J
    BRAUN, J
    HEINDRICHS, U
    DREUW, B
    SCHUMPELICK, V
    RAU, G
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1994, 29 (08) : 693 - 702
  • [6] Comparison between intraluminal multiple electric impedance measurement and manometry in the human oesophagus
    Frieling, T
    Hermann, S
    Kuhlbusch, R
    Enck, P
    Silny, J
    Lubke, HJ
    Strohmeyer, G
    Haeussinger, D
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 1996, 8 (01) : 45 - 50
  • [7] COMPARISON OF ESOPHAGEAL MANOMETRY, PROVOCATIVE TESTING, AND AMBULATORY MONITORING IN PATIENTS WITH UNEXPLAINED CHEST PAIN
    HEWSON, EG
    DALTON, CB
    RICHTER, JE
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1990, 35 (03) : 302 - 309
  • [8] EFFECT OF PERISTALTIC DYSFUNCTION ON ESOPHAGEAL VOLUME CLEARANCE
    KAHRILAS, PJ
    DODDS, WJ
    HOGAN, WJ
    [J]. GASTROENTEROLOGY, 1988, 94 (01) : 73 - 80
  • [9] Dynamics of esophageal bolus transport in healthy subjects studied using multiple intraluminal impedancometry
    Nguyen, HN
    Silny, J
    Albers, D
    Roeb, E
    Gartung, C
    Rau, G
    Matern, S
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 1997, 273 (04): : G958 - G964
  • [10] Multiple intraluminal electrical impedancometry for recording of upper gastrointestinal motility: Current results and further implications
    Nguyen, HN
    Silny, J
    Matern, S
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 1999, 94 (02) : 306 - 317