Subharmonic contrast intravascular ultrasound for vasa vasorum imaging

被引:115
作者
Goertz, David E. [1 ,2 ]
Frijlink, Martijn E. [1 ]
Tempel, Dennie [1 ]
Bhagwandas, Vijay [1 ,3 ]
Gisolf, Andries
Krams, Robert [1 ]
de Jong, Nico [1 ,2 ,4 ]
van der Steen, Antonius F. W. [1 ,2 ]
机构
[1] Erasmus MC, Dept Biomed Engn, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Delft Univ Technol, Delft, Netherlands
[4] Univ Twente, NL-7500 AE Enschede, Netherlands
关键词
intravascular ultrasound; subharmonic; nonlinear; contrast agents; microbubbles; vasa vasorum; atherosclerosis; coronary artery; vulnerable plaque;
D O I
10.1016/j.ultrasmedbio.2007.05.023
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The feasibility of subharmonic contrast intravascular ultrasound (IVUS) imaging was investigated using a prototype nonlinear IVUS system and the commercial contrast agent Definity (TM). The system employed a mechanically scanned commercial catheter with a custom transducer element fabricated to have sensitivity at both 15 and 30 MHz. Experiments were conducted at a fundamental frequency of 30 MHz (F30; 25% bandwidth), with on-axis pressures ranging from 0.12 to 0.79 MPa, as measured with a needle hydrophone. In vitro characterization experiments demonstrated the detection of 15 MHz subharmonic signals (SH15) when pressure levels reached 360 kPa. The formation of SH15 images was shown, with tissue signals suppressed to near the noise floor and contrast to tissue ratios were improved by up to 30 dB relative to F30. In vivo experiments were performed using the atherosclerotic rabbit aorta model. Following the bolus injection of contrast agent upstream of the imaging catheter, agent was detected within the aorta, vena cava and within the perivascular space. These results provide a first in vivo demonstration of subharmonic contrast IVUS and suggest its potential as a new technique for imaging vasa vasorum. (E-mail: goertz@sri.utoronto.ca) (c) 2007 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1859 / 1872
页数:14
相关论文
共 67 条
[1]  
BAMBER JC, 2004, PHYS PRINCIPLES MED, P188
[2]   Nonlinear coded excitation method for ultrasound contrast imaging [J].
Borsboom, JMG ;
Chin, CT ;
de Jong, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (02) :277-284
[3]   Ultrasound contrast agent in intravascular echography: An in vitro study [J].
Cachard, C ;
Finet, G ;
Bouakaz, A ;
Tabib, A ;
Francon, D ;
Gimenez, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :705-717
[4]   Vasa vasorum imaging: A new window to the clinical detection of vulnerable atherosclerotic plaques [J].
Carlier S. ;
Kakadiaris I.A. ;
Dib N. ;
Vavuranakis M. ;
Stefanadis C. ;
O'Malley S.M. ;
Hartley C.J. ;
Metcalfe R. ;
Mehran R. ;
Falk E. ;
Gul K. ;
Naghavi M. .
Current Atherosclerosis Reports, 2005, 7 (2) :164-169
[5]  
Cheung K, 2005, ULTRASON, P850
[6]   Leucocyte recruitment in rupture prone regions of lipid-rich plaques: a prominent role for neovascularization? [J].
de Boer, OJ ;
van der Wal, AC ;
Teeling, P ;
Becker, AE .
CARDIOVASCULAR RESEARCH, 1999, 41 (02) :443-449
[7]   Contrast harmonic imaging [J].
de Jong, N ;
Bouakaz, A ;
Ten Cate, FJ .
ULTRASONICS, 2002, 40 (1-8) :567-573
[8]   Elastic and acoustic properties of vessel mimicking material for elasticity imaging [J].
deKorte, CL ;
Cespedes, EI ;
vanderSteen, AFW ;
Norder, B ;
Nijenhuis, KT .
ULTRASONIC IMAGING, 1997, 19 (02) :112-126
[9]   In vivo targeting of acoustically reflective liposomes for intravascular and transvascular ultrasonic enhancement [J].
Demos, SM ;
Alkan-Onyuksel, H ;
Kane, BJ ;
Ramani, K ;
Nagaraj, A ;
Greene, R ;
Klegerman, M ;
McPherson, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (03) :867-875
[10]   BASIC FIBROBLAST GROWTH-FACTOR ENHANCES THE COUPLING OF INTIMAL HYPERPLASIA AND PROLIFERATION OF VASA VASORUM IN INJURED RAT ARTERIES [J].
EDELMAN, ER ;
NUGENT, MA ;
SMITH, LT ;
KARNOVSKY, MJ .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 89 (02) :465-473