Correlation of femoral and lumbar DXA and calcaneal ultrasound, measured in situ with intact soft tissues, with the in vitro failure loads of the proximal femur

被引:67
作者
Lochmüller, EM
Zeller, JB
Kaiser, D
Eckstein, F
Landgraf, J
Putz, R
Steldinger, R
机构
[1] Univ Munich, Frauenklin 1, D-80337 Munich, Germany
[2] Univ Munich, Anat Anstalt, D-8000 Munich, Germany
关键词
bone mineral density; DXA; femoral failure loads; hip fracture; osteoporosis; ultrasound;
D O I
10.1007/s001980050104
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The objective of this study was to determine experimentally the sex-specific correlation of femoral and lumbar DXA and calcaneal ultrasound, measured in situ, with the in vitro failure loads of the proximal femur. Fifty-eight cadavers with intact skin and soft tissues (34 male, aged 81.2 +/- 8.7 years; 24 female, aged 83.7 +/- 10.6 years) were examined. The bone mass of the proximal femur and the lumbar spine were determined using dual-energy X-ray absorptiometry and the ultrasonic properties of the calcaneus with quantitative ultrasound. Afterwards, the right femora were excised 18 cm distal to the minor trochanter, and their load to failure determined with a material testing machine. Femoral fracture loads were significantly higher in males than in females, both before and after correcting for body height and weight. Femoral neck bone mineral density (BMD) was significantly correlated with femoral failure loads (r=0.65 all specimens, 0.57 males (0.64 after excluding trochanteric fractures) and 0.77 females; p <0.001). The correlations with the ultrasonic Stiffness Index of the calcaneus were in a similar range (r = 0.67 all specimens, 0.48 males (0.64 after excluding trochanteric fractures) and 0.65 females; p <0.001). The correlations between femoral failure loads and the spinal BMD were lower (r=0.40, p <0.01), particularly in males (r=0.30, not significant). In contrast to previous experimental investigations on excised bones, our results are consistent with clinical studies that have reported that ultrasound and femoral DXA have a similar ability to predict the risk of hip fracture.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 20 条
[1]
Single and dual energy X-ray absorptiometry [J].
Adams, JE .
EUROPEAN RADIOLOGY, 1997, 7 (Suppl 2) :S20-S31
[2]
Augat P, 1996, J BONE MINER RES, V11, P1356
[3]
Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women - A prospective study [J].
Bauer, DC ;
Gluer, CC ;
Cauley, JA ;
Vogt, TM ;
Ensrud, KE ;
Genant, HK ;
Black, DM .
ARCHIVES OF INTERNAL MEDICINE, 1997, 157 (06) :629-634
[4]
PREDICTING FEMORAL-NECK STRENGTH FROM BONE-MINERAL DATA - A STRUCTURAL APPROACH [J].
BECK, TJ ;
RUFF, CB ;
WARDEN, KE ;
SCOTT, WW ;
RAO, GU .
INVESTIGATIVE RADIOLOGY, 1990, 25 (01) :6-18
[5]
Anteroposterior and lateral spinal DXA for the assessment of vertebral body strength: Comparison with hip and forearm measurement [J].
Bjarnason, K ;
Hassager, C ;
Svendsen, OL ;
Christiansen, C .
OSTEOPOROSIS INTERNATIONAL, 1996, 6 (01) :37-42
[6]
ULTRASOUND AND DENSITOMETRY OF THE CALCANEUS CORRELATE WITH THE FAILURE LOADS OF CADAVERIC FEMURS [J].
BOUXSEIN, ML ;
COURTNEY, AC ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (02) :99-103
[7]
Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[8]
FORMALIN FIXATION EFFECTS ON VERTEBRAL BONE-DENSITY AND FAILURE MECHANICS - AN IN-VITRO STUDY OF HUMAN AND SHEEP VERTEBRAE [J].
EDMONDSTON, SJ ;
SINGER, KP ;
DAY, RE ;
BREIDAHL, PD ;
PRICE, RI .
CLINICAL BIOMECHANICS, 1994, 9 (03) :175-179
[9]
Genant HK, 1996, J BONE MINER RES, V11, P707
[10]
FALL SEVERITY AND BONE-MINERAL DENSITY AS RISK-FACTORS FOR HIP FRACTURE IN AMBULATORY ELDERLY [J].
GREENSPAN, SL ;
MYERS, ER ;
MAITLAND, LA ;
RESNICK, NM ;
HAYES, WC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (02) :128-133