Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis:: a prospective, randomized trial

被引:100
作者
Pache, J
Dibra, A
Mehilli, J
Dirschinger, J
Schömig, A
Kastrati, A
机构
[1] Deutsch Herzzentrum, D-80636 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-8000 Munich, Germany
关键词
drug-etuting stents; restenosis; sirolimus; stents;
D O I
10.1093/eurheartj/ehi098
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Drug-eluting stents have considerably reduced restenosis. Their relative merits have been assessed on the basis of comparisons made with control bare stents with thick struts. However, increased strut thickness negatively affects restenosis. No direct comparisons between drug-eluting stents and bare stents with thin struts have been performed. The aim of this study was to evaluate the relative efficacy of sirolimus-eluting stents (Cypher (TM)) as compared with that of bare stents, with thin struts (BeStent (TM) 2). Methods and results A total of 500 patients with coronary artery disease were randomly assigned to receive a Cypher stent or BeStent. The primary endpoint was angiographic restenosis defined as a stenosis diameter >= 50% at 6-month angiographic follow-up. The secondary endpoint was the need for target vessel revascularization (TVR) during the year following the procedure. Follow-up angiography was performed in 81.8% of the patients. Patients treated with Cypher stents had a lower angiographic restenosis rate (8.3 vs. 25.5%, relative risk, 0.33 (95% confidence interval, 0.19 - 0.56), P < 0.001] and a tower incidence of TVR [7.2 vs. 18.8%, relative risk, 0.38 (0.22 - 0.66), P < 0.001]. For smaller vessels (< 2.8 mm), the angiographic restenosis rates were 7.0% with the Cypher stent and 34.2% with the BeStent (P < 0.001). For larger vessels (>= 2.8 mm), angiographic restenosis rates were 10.0% with the Cypher stent and 13.1% with the BeStent (P = 0.52). Conclusion The drug-eluting stent, Cypher, is associated with a significantly lower risk of restenosis compared with the bare thin-strut BeStent. The advantage of the Cypher stent is vastly reduced in large vessels.
引用
收藏
页码:1262 / 1268
页数:7
相关论文
共 31 条
  • [1] In-stent restenosis in small coronary arteries - Impact of strut thickness
    Briguori, C
    Sarais, C
    Pagnotta, P
    Liistro, F
    Montorfano, M
    Chieffo, A
    Sgura, F
    Corvaja, N
    Albiero, R
    Stankovic, G
    Toutoutzas, C
    Bonizzoni, E
    Di Mario, C
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) : 403 - 409
  • [2] Cost-effectiveness of sirolimus-eluting stents for treatment of complex coronary stenoses - Results from the sirolimus-eluting balloon expandable stent in the treatment of patients with de novo native coronary artery lesions (SIRIUS) trial
    Cohen, DJ
    Bakhai, A
    Shi, CX
    Githiora, L
    Lavelle, T
    Berezin, RH
    Leon, MB
    Moses, JW
    Carrozza, JP
    Zidar, JP
    Kuntz, RE
    [J]. CIRCULATION, 2004, 110 (05) : 508 - 514
  • [3] Stent placement to prevent restenosis after angioplasty in small coronary arteries
    Doucet, S
    Schalij, MJ
    Vrolix, MCM
    Hilton, D
    Chenu, P
    de Bruyne, B
    Udayachalerm, W
    Seth, A
    Bilodeau, L
    Reiber, JHC
    Harel, F
    Lespérance, J
    [J]. CIRCULATION, 2001, 104 (17) : 2029 - 2033
  • [4] Vessel size and long-term outcome after coronary stent placement
    Elezi, S
    Kastrati, A
    Neumann, FJ
    Hadamitzky, M
    Dirschinger, J
    Schömig, A
    [J]. CIRCULATION, 1998, 98 (18) : 1875 - 1880
  • [5] CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION
    ELLIS, SG
    VANDORMAEL, MG
    COWLEY, MJ
    DISCIASCIO, G
    DELIGONUL, U
    TOPOL, EJ
    BULLE, TM
    [J]. CIRCULATION, 1990, 82 (04) : 1193 - 1202
  • [6] Pathology of acute and chronic coronary stenting in humans
    Farb, A
    Sangiorgi, G
    Carter, AJ
    Walley, VM
    Edwards, WD
    Schwartz, RS
    Virmani, R
    [J]. CIRCULATION, 1999, 99 (01) : 44 - 52
  • [7] Morphological predictors of restenosis after coronary stenting in humans
    Farb, A
    Weber, DK
    Kolodgie, FD
    Burke, AP
    Virmani, R
    [J]. CIRCULATION, 2002, 105 (25) : 2974 - 2980
  • [8] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [9] Can we afford to eliminate restenosis? Can we afford not to?
    Greenberg, D
    Bakhai, A
    Cohen, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) : 513 - 518
  • [10] Kastrati A, 2000, CATHETER CARDIO INTE, V50, P290, DOI 10.1002/1522-726X(200007)50:3<290::AID-CCD5>3.0.CO