Determination of regional ventilation and perfusion in the lung using xenon and computed tomography

被引:62
作者
Kreck, TC
Krueger, MA
Altemeier, WA
Sinclair, SE
Robertson, HT
Shade, ED
Hildebrandt, J
Lamm, WJE
Frazer, DA
Polissar, NL
Hlastala, MP
机构
[1] Univ Washington, Div Pulm & Crit Care Med, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Seattle, WA 98195 USA
[3] Mt Whisper Light Stat Consulting, Seattle, WA 98112 USA
关键词
functional imaging; in vivo imaging; gas exchange; blood solubility; recirculation;
D O I
10.1152/jappl.2001.91.4.1741
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We propose a model to measure both regional ventilation ((V) over dot) and perfusion ((Q) over dot) in which the regional radiodensity (RD) in the lung during xenon (Xe) washin is a function of regional (V) over dot (increasing RD) and (Q) over dot (decreasing RD). We studied five anesthetized, paralyzed, mechanically ventilated, supine sheep. Four 2.5-mm-thick computed tomography (CT) images were simultaneously acquired immediately cephalad to the diaphragm at end inspiration for each breath during 3 min of Xe breathing. Observed changes in RD during Xe washin were used to determine regional (V) over dot and (Q) over dot. For 16 mm(3), displayed more variance than (V) over dot: the coefficient of variance of (Q) over dot (CV(Q) over dot) = 1.58 +/- 0.23, the CV of (V) over dot (CV(V) over dot) = 0.46 +/- 0.07, and the ratio of CV(Q) over dot to CV(V) over dot = 3.5 +/- 1.1. CV(Q) over dot (1.21 +/- 0.37) and the ratio of CV(Q) over dot to CV(V) over dot (2.4 +/- 1.2) were smaller at 1,000-mm(3) scale, but CV(V) over dot (0.53 +/- 0.09) was not, (V) over dot/(Q) over dot distributions also displayed scale dependence: log SD of (V) over dot and log SD of (Q) over dot were 0.79 +/- 0.05 and 0.85 +/- 0.10 for 16-mm(3) and 0.69 +/- 0.20 and 0.67 +/- 0.10 for 1,000-mm(3) regions of lung, respectively. (V) over dot and (Q) over dot measurements made with CT and Xe also demonstrate vertically oriented and isogravitational heterogeneity, which are described using other methodologies. Sequential images acquired by CT during Xe breathing can be used to determine both regional (V) over dot and (Q) over dot noninvasively with high spatial resolution.
引用
收藏
页码:1741 / 1749
页数:9
相关论文
共 45 条
[1]  
Almquist H, 1999, CLIN PHYSIOL, V19, P475
[2]   Pulmonary embolization causes hypoxemia by redistributing regional blood flow without changing ventilation [J].
Altemeier, WA ;
Robertson, HT ;
McKinney, S ;
Glenny, RW .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (06) :2337-2343
[3]   Fractal nature of regional ventilation distribution [J].
Altemeier, WA ;
McKinney, S ;
Glenny, RW .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (05) :1551-1557
[4]   RELATIONSHIPS BETWEEN REGIONAL VENTILATION AND VASCULAR AND EXTRAVASCULAR VOLUME IN SUPINE HUMANS [J].
BRUDIN, LH ;
RHODES, CG ;
VALIND, SO ;
JONES, T ;
JONSON, B ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (03) :1195-1204
[5]  
BRUDIN LH, 1994, J APPL PHYSL, V76
[6]   EFFECTS OF PULMONARY BLOOD-FLOW ON THE FRACTAL NATURE OF FLOW HETEROGENEITY IN SHEEP LUNGS [J].
CARUTHERS, SD ;
HARRIS, TR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (03) :1474-1479
[7]   TISSUE-BLOOD PARTITION-COEFFICIENT FOR XENON - TEMPERATURE AND HEMATOCRIT DEPENDENCE [J].
CHEN, RYZ ;
FAN, FC ;
KIM, S ;
JAN, KM ;
USAMI, S ;
CHIEN, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (02) :178-183
[8]   PULMONARY GAS-EXCHANGE DURING ALTERED DENSITY GAS BREATHING [J].
CHRISTOPHERSON, SK ;
HLASTALA, MP .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (01) :221-225
[9]   THE ANESTHETIC PROPERTIES OF XENON IN ANIMALS AND HUMAN BEINGS, WITH ADDITIONAL OBSERVATIONS ON KRYPTON [J].
CULLEN, SC ;
GROSS, EG .
SCIENCE, 1951, 113 (2942) :580-582
[10]   SOLUBILITY COEFFICIENTS OF XE-133 IN WATER, SALINE, DOG-BLOOD AND ORGANS [J].
ERCAN, MT .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1979, 30 (12) :757-759