Capillary electrophoresis-electrospray mass spectra of the herbicides paraquat and diquat

被引:44
作者
Song, XB
Budde, WL
机构
[1] US EPA, OFF RES & DEV, NATL EXPOSURE RES LAB, CINCINNATI, OH 45268 USA
[2] OAK RIDGE INST SCI & EDUC, CINCINNATI, OH USA
关键词
D O I
10.1016/1044-0305(96)00070-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The positive ion electrospray mass spectra of the quaternary ammonium salt herbicides paraquat and diquat are examined by on-line separation with capillary electrophoresis (CE) and by direct infusion of the analytes. The analytes are separated by CE in 7-10 min at pH 3.9 in 50% methanol-water by using several different separation buffer electrolytes. The capillary electrophoresis-electrospray ionization (CE-ES) mass spectra of paraquat and diquat consist primarily of doubly charged molecular ions, singly charged molecular ions, and singly charged deprotonated ions. The direct infusion spectra consist primarily of doubly charged molecular ions and singly charged deprotonated ions. The relative abundances of the doubly charged and deprotonated ions depend strongly on the presence or absence of ammonium ion in the CE separation buffer or the direct infusion solution. A deprotonation mechanism is proposed in which the free base ammonia is the deprotonating agent in the desolvating charged droplets or in the gas phase. The analytical potential of the CE-ES electrospray approach for environmental analyses is evaluated in terms of the precision of replicate injections, linear concentration range, and estimated detection Limit.
引用
收藏
页码:981 / 986
页数:6
相关论文
共 10 条
[1]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[2]   ONLINE ISOTACHOPHORETIC SAMPLE PRETREATMENT IN ULTRATRACE DETERMINATION OF PARAQUAT AND DIQUAT IN WATER BY CAPILLARY ZONE ELECTROPHORESIS [J].
KANIANSKY, D ;
IVANYI, F ;
ONUSKA, FI .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1817-1824
[3]   EFFECTS OF ANIONS ON THE POSITIVE-ION ELECTROSPRAY-IONIZATION MASS-SPECTRA OF PEPTIDES AND PROTEINS [J].
MIRZA, UA ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2898-2904
[4]   SAMPLING AND ANALYSIS OF AIRBORNE RESIDUES OF PARAQUAT IN TREATED COTTON FIELD ENVIRONMENTS [J].
SEIBER, JN ;
WOODROW, JE .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1981, 10 (02) :133-149
[5]   CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING AN ELECTROSPRAY IONIZATION INTERFACE [J].
SMITH, RD ;
OLIVARES, JA ;
NGUYEN, NT ;
UDSETH, HR .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :436-441
[6]  
*US DEP COMM NAT I, NIST EPA NIH MASS SP
[8]   ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR PARAQUAT AND ITS APPLICATION TO EXPOSURE ANALYSIS [J].
VANEMON, J ;
HAMMOCK, B ;
SEIBER, JN .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1866-1873
[9]  
ZEN J, 1996, ANAL CHEM, V86, P498
[10]  
1996, CHEM ENG NEWS 0304, P6