摘要
The use of ion-spray mass spectrometry rendered it possible to characterize the signals obtained during studies of the polymorphism of metallothionein (MT) by reversed-phase (RP) HPLC in terms of the molecular mass. Artefact signals due to incomplete metallation, exchange of metals with the impurities of the column stationary phase and cross-contamination of the preparations purified by size-exclusion and anion-exchange chromatography may be present. On the other hand, some signals in RP HPLC with UV detection considered to belong to a single species were found to be composed of several complexes eluting precisely at the same time. On-line electrospray mass spectrometry was used to systematize the knowledge of the MT isoforms and subisoforms by attributing to each of the eluting peaks the molecular mass of the form involved and can be used to compare the results obtained for the different groups. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 18 条
[1]   HIGH-PERFORMANCE LIQUID-C CHROMATOGRAPHY FOR STUDYING METALLOTHIONEIN POLYMORPHISM [J].
BORDIN, G ;
RAPOSO, FC ;
RODRIGUEZ, AR .
CANADIAN JOURNAL OF CHEMISTRY, 1994, 72 (05) :1238-1245
[2]   Speciation of metal complexes with biomolecules by reversed-phase HPLC with ion-spray and inductively coupled plasma mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :267-273
[3]  
HAMER DH, 1993, METALLOTHIONEIN, pR3
[4]  
HE T, 1997, P 45 ASMS C MASS SPE
[5]   PHYSICOCHEMICAL CHARACTERIZATION OF METAL-BINDING PROTEINS USING HPLC-ICP-MS, HPLC-MA-AAS AND ELECTROSPRAY-MS [J].
HIGH, KA ;
METHVEN, BA ;
MCLAREN, JW ;
SIU, KWM ;
WANG, J ;
KLAVERKAMP, JF ;
BLAIS, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :393-402
[6]  
KAGI JHR, 1993, METALLOTHIONEIN, pR3
[7]  
KIMURA M, 1979, METALLOTHIONEIN
[8]   CHARACTERIZATION OF ISOPROTEIN PATTERNS IN TISSUE-EXTRACTS AND ISOLATED SAMPLES OF METALLOTHIONEINS BY REVERSE-PHASE HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
KLAUSER, S ;
KAGI, JHR ;
WILSON, KJ .
BIOCHEMICAL JOURNAL, 1983, 209 (01) :71-80
[9]   Analysis for metallothioneins using coupled techniques [J].
Lobinski, R ;
Chassaigne, H ;
Szpunar, J .
TALANTA, 1998, 46 (02) :271-289
[10]  
RICHARDS MP, 1991, METHOD ENZYMOL, V205, P217