Solid-phase micro-extraction-gas chromatography-(tandem) mass spectrometry as a tool for pesticide residue analysis in water samples at high sensitivity and selectivity with confirmation capabilities

被引:84
作者
Gonçalves, C
Alpendurada, MF
机构
[1] Univ Porto, Fac Pharm, Hydrol Lab, P-4050047 Oporto, Portugal
[2] IAREN, Water Inst No Reg, P-4450113 Matosinhos, Portugal
关键词
water analysis; pesticides;
D O I
10.1016/j.chroma.2003.10.117
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography-mass spectrometry (GC-MS) has been widely applied for pesticide monitoring because of its high sensitivity and specificity and for the potential of multi-residue and multi-class analysis. An analytical procedure was developed for the determination of pesticide multi-residues in water samples combining solid-phase micro-extraction (SPME) and gas chromatography-ion trap mass spectrometry. For SPME extraction a poly(dimethylsiloxane)-divinylbenzene coated fibre was selected whereas the mass spectrometer was operated under full scan, selected ion storage (SIS), muSIS (SIM) and MS-MS and the figures of merit compared. Quantitative and qualitative (confirmatory) capabilities of each operation mode are discussed. Using MS-MS, precision was typically below 10% and limits of detection (LODs) were improved by 1.3 to 20 times (to low- or sub-ppt levels) compared to muSIS, with the advantage of maintaining identification capabilities. The combination of selective extraction by SPME and highly selective determination by GC-MS-MS made possible ultra-selective and essentially error-free determination of pesticides in complex environmental samples. This aspect will be highlighted in the paper. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 27 条
  • [1] Monitoring of priority pesticides and other organic pollutants in river water from Portugal by gas chromatography-mass spectrometry and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry
    Azevedo, DD
    Lacorte, S
    Vinhas, T
    Viana, P
    Barceló, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) : 13 - 26
  • [2] Baez ME, 1999, BOL SOC CHIL QUIM, V44, P217
  • [3] Barcelo D., 1997, Trace Determination of Pesticides and Their Degradation Products in Water
  • [4] Simultaneous determination of 60 pesticides in water using solid-phase microextraction and gas chromatography mass spectrometry
    BoydBoland, AA
    Magdic, S
    Pawliszyn, JB
    [J]. ANALYST, 1996, 121 (07) : 929 - 937
  • [5] Simultaneous optimization of the solid-phase extraction of organochlorine and organophosphorus pesticides using the desirability function
    Carro, AM
    Lorenzo, RA
    [J]. ANALYST, 2001, 126 (07) : 1005 - 1010
  • [6] Multi-residue methodology for pesticide screening in wines
    Correia, M
    Delerue-Matos, C
    Alves, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) : 59 - 67
  • [7] Deger AB, 2000, ACTA HYDROCH HYDROB, V28, P292, DOI 10.1002/1521-401X(200012)28:6<292::AID-AHEH292>3.0.CO
  • [8] 2-I
  • [9] Comparative study using ECD, NPD, and MS/MS chromatographic techniques in the determination of pesticides in wetland waters
    Espada, MCP
    Frenich, AG
    Vidal, JLM
    Parrilla, P
    [J]. ANALYTICAL LETTERS, 2001, 34 (04) : 597 - 614
  • [10] Comparison of gas chromatography with NPD, MS, and tandem MS-MS in the multiresidue analysis of pesticides in environmental waters
    Frenich, AG
    Vidal, JLM
    Espada, MCP
    García, MDG
    Arrebola, FJ
    [J]. CHROMATOGRAPHIA, 2000, 52 (9-10) : 614 - 620