Cast thin film biosensor design based on a nafion backbone, a multiwalled carbon nanotube conduit, and a glucose oxidase function

被引:199
作者
Tsai, YC [1 ]
Li, SC [1 ]
Chen, JM [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
关键词
D O I
10.1021/la0470535
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Novel electroanalytical sensing nanobiocomposite materials are reported. These materials are prepared by mixing multiwalled carbon nanotubes (MWNTs), a Nafion cation exchanger, and glucose oxidase (GOD) in appropriate amounts. The MWNTs are cylindrical with a diameter in the range 40-60 nm and with a length of up to several micrometers, and they provide electrical conductivity. Nafion acts as a polymer backbone to give stable and homogeneous cast thin films. Both MWNTs and Nafion provide negative functionalities to bind to positively charged redox enzymes such as glucose oxidase. The resulting biosensing composite material is inexpensive, reliable, and easy to use. The homogeneity of the MWNT-Nafion-GOD nanobiocomposite films was characterized by atomic force microscopy (AFM). Amperometric transducers fabricated with these materials were characterized electrochemically using cyclic voltammetry and amperometry in the presence of hydrogen peroxide and in the presence of glucose. Their linear response to hydrogen peroxide was demonstrated. The glucose biosensor sensitivity was strongly influenced by the glucose oxidase concentration within the nanobiocomposite film. The optimized glucose biosensor (2.5 mg/mL GOD) displayed a sensitivity of 330 nA/mM, a linear range of up to 2 mM, a detection limit of 4 mu M, and a response time of < 3 s.
引用
收藏
页码:3653 / 3658
页数:6
相关论文
共 38 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Carbon-polymer biocomposites for amperometric sensing [J].
Alegret, S ;
Cespedes, F ;
MartinezFabregas, E ;
Martorell, D ;
Morales, A ;
Centelles, E ;
Munoz, J .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :35-44
[3]   Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis [J].
Badea, M ;
Curulli, A ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :689-698
[4]   Investigation of modified basal plane pyrolytic graphite electrodes: definitive evidence for the electrocatalytic properties of the ends of carbon nanotubes [J].
Banks, CE ;
Moore, RR ;
Davies, TJ ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2004, (16) :1804-1805
[5]   Carbon nanotube actuators [J].
Baughman, RH ;
Cui, CX ;
Zakhidov, AA ;
Iqbal, Z ;
Barisci, JN ;
Spinks, GM ;
Wallace, GG ;
Mazzoldi, A ;
De Rossi, D ;
Rinzler, AG ;
Jaschinski, O ;
Roth, S ;
Kertesz, M .
SCIENCE, 1999, 284 (5418) :1340-1344
[6]   Enzyme-coated carbon nanotubes as single-molecule biosensors [J].
Besteman, K ;
Lee, JO ;
Wiertz, FGM ;
Heering, HA ;
Dekker, C .
NANO LETTERS, 2003, 3 (06) :727-730
[7]   UV-Spectrophotometry and square wave voltammetry at nafion-modified carbon-paste electrode for the determination of doxazosin in urine and formulations [J].
de Betoño, SF ;
Garcia, AA ;
Valentín, JFA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (04) :621-630
[8]   Enzyme immunoassay technique using alkaline phosphatase enzyme labels and a Nafion electrode as sensor [J].
Degrand, C ;
Limoges, B ;
Rapicault, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1343-1349
[9]   A CARBON NANOTUBE FIELD-EMISSION ELECTRON SOURCE [J].
DEHEER, WA ;
CHATELAIN, A ;
UGARTE, D .
SCIENCE, 1995, 270 (5239) :1179-1180
[10]  
EGGINS BR, 2002, CHEM SENSORS BIOSENS, P100