Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection

被引:97
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
ATP; 9,10-anthraquinone-2,6-disulfonate; photochemical reaction; flow injection; chemiluminescence detection;
D O I
10.1007/s00216-003-2071-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of ATP using the coupling between a photochemical reaction and a chemiluminescence reaction in a flow injection (FI) system is described. The method is based on the reaction of glucose with ATP catalyzed by hexokinase and Mg2+ ions. The glucose that is not consumed by ATP is subsequently photooxidized using 9,10-anthraquinone-2,6-disulfonate as a sensitizer. The hydrogen peroxide produced in the photochemical reaction is monitored through the chemiluminescence reaction with luminol catalyzed by hematine. There is a linear relationship between the decrease in the chemiluminescence response and the ATP concentration at a constant concentration of glucose. Under the optimum conditions, the calibration graph is linear in the range 0.20-50.5 mg L-1 with a throughput of 25 samples per hour and relative standard deviations between +/-0.62 and +/-1.42%. The limit of detection is 0.07 mg L-1. The method was used for the determination of ATP in pharmaceuticals, milk, and soils.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 37 条
[1]   NA+,K+-ATPASE-BASED BILAYER-LIPID MEMBRANE SENSOR FOR ADENOSINE 5'-TRIPHOSPHATE [J].
ADACHI, Y ;
SUGAWARA, M ;
TANIGUCHI, K ;
UMEZAWA, Y .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :577-584
[2]  
[Anonymous], 1977, CELLULAR ENERGY META
[3]   A SIMPLE EFFECTIVE PROCEDURE FOR THE DETERMINATION OF ADENOSINE-TRIPHOSPHATE IN SOILS [J].
BAI, QY ;
ZELLES, L ;
SCHEUNERT, I ;
KORTE, F .
CHEMOSPHERE, 1988, 17 (12) :2461-2470
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE SIMULTANEOUS DETERMINATION OF MYOCARDIAL CREATINE-PHOSPHATE AND ADENOSINE NUCLEOTIDES [J].
BEDFORD, GK ;
CHIONG, MA .
JOURNAL OF CHROMATOGRAPHY, 1984, 305 (01) :183-187
[5]  
BERGMEYER HU, 1984, METHOD ENZYMAT AN, P340
[6]  
BROLIN S, 1992, BIOLUMINESCENCE ANAL, P47
[7]   BIOLUMINESCENT CONTINUOUS-FLOW ASSAY OF ADENOSINE 5'-TRIPHOSPHATE USING FIREFLY LUCIFERASE IMMOBILIZED ON NYLON TUBES [J].
CARREA, G ;
BOVARA, R ;
MAZZOLA, G ;
GIROTTI, S ;
RODA, A ;
GHINI, S .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :331-333
[8]   Glucose oxidase/hexokinase electrode for the determination of ATP [J].
Compagnone, D ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :109-113
[9]   FAST REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NUCLEOTIDES IN RED-BLOOD-CELLS [J].
CRESCENTINI, G ;
STOCCHI, V .
JOURNAL OF CHROMATOGRAPHY, 1984, 290 (MAY) :393-399
[10]  
DELUCA M, 1976, ADV ENZYMOL RAMB, V44, P37