Neonatal mechanical bridging to total orthotopic heart transplantation

被引:21
作者
Weyand, M
Kececioglu, D
Kehl, HG
Schmid, C
Loick, HM
Vogt, J
Scheld, HH
机构
[1] Univ Munster, Dept Cardiothorac Surg, D-48129 Munster, Germany
[2] Univ Munster, Dept Pediat Cardiol, D-4400 Munster, Germany
[3] Univ Munster, Dept Anesthesia & Intens Care Med, D-4400 Munster, Germany
关键词
D O I
10.1016/S0003-4975(98)00442-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Until recently, newborns with medically intractable cardiac failure caused by congenital malformations were mostly doomed to death because of the severity of the disease, which precludes a palliative operation, or because of fatal deterioration before availability of a suitable donor heart. Methods. The recently developed paracorporeal pneumatically driven Medos HIA ventricular assist device offers a therapeutic option for these small infants because it is manufactured in various sizes and is even suitable for cardiac assistance in neonates with a body surface area less than 0.3 m(2). Results. We report our initial experience with this device, which we used for univentricular bridging to total orthotopic cardiac transplantation in 3 infants. The device was inserted to support the left ventricle in two instances and to support the right heart in one. Successful bridging to transplantation was achieved in 2 infants for periods of 2 and 7 weeks. Conclusions. Our experience demonstrates the feasibility of univentricular mechanical support followed by successful cardiac transplantation in infants and newborns. (C)1998 by The Society of Thoracic Surgeons.
引用
收藏
页码:519 / 522
页数:4
相关论文
共 11 条
  • [1] THE NATURAL-HISTORY OF THE HYPOPLASTIC LEFT HEART SYNDROME
    ALLAN, LD
    SHARLAND, G
    TYNAN, MJ
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1989, 25 (03) : 341 - 343
  • [2] BABATASI G, 1997, CARDIOVASC ENG, V2, P16
  • [3] CARPENTIER A, 1988, J THORAC CARDIOV SUR, V96, P92
  • [4] DESIGN IMPROVEMENTS OF THE HIA-VAD BASED ON ANIMAL-EXPERIMENTS
    EILERS, R
    HARBOTT, P
    REUL, H
    RAKHORST, G
    RAU, G
    [J]. ARTIFICIAL ORGANS, 1994, 18 (07) : 473 - 478
  • [5] FRAZIER OH, 1992, J HEART LUNG TRANSPL, V11, P530
  • [6] EXPERIENCE WITH UNIVENTRICULAR SUPPORT IN MORTALLY ILL CARDIAC TRANSPLANT CANDIDATES
    KORMOS, RL
    BOROVETZ, HS
    GASIOR, T
    ANTAKI, JF
    ARMITAGE, JM
    PRISTAS, JM
    HARDESTY, RL
    GRIFFITH, BP
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (02) : 261 - 272
  • [7] PHYSIOLOGIC REPAIR OF AORTIC ATRESIA HYPOPLASTIC LEFT HEART SYNDROME
    NORWOOD, WI
    LANG, P
    HANSEN, DD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (01) : 23 - 26
  • [8] IN-VIVO EVALUATION OF THE HIA-VAD - A NEW GERMAN VENTRICULAR ASSIST DEVICE
    RAKHORST, G
    HENSENS, AG
    VERKERKE, GJ
    BLANKSMA, PK
    BOM, VJJ
    ELSTRODT, J
    MAGIELSE, CPE
    VANDERMEER, J
    EILERS, R
    RUEL, H
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1994, 42 (03) : 136 - 140
  • [9] Beating heart implantation of a wearable NOVACOR left-ventricular assist device
    Scheld, HH
    Hammel, D
    Schmid, C
    Weyand, M
    Deng, M
    Mollhoff, T
    Kerber, S
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1996, 44 (02) : 62 - 66
  • [10] Successful bridging to cardiac transplantation in a dystrophic infant with the use of a new paracorporeal pneumatic pump
    Weyand, M
    Kececioglu, D
    Schmid, C
    Kehl, HG
    Tandler, R
    Loick, HM
    Scheld, HH
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (03) : 505 - 507