Validation of a vision-based, three-dimensional facial imaging system

被引:122
作者
Ayoub, A
Garrahy, A
Hood, C
White, J
Bock, M
Siebert, JP
Spencer, R
Ray, A
机构
[1] Glasgow Dent Hosp & Sch, Biotechnol & Craniofacial Res Sect, BACS, Glasgow G2 3JZ, Lanark, Scotland
[2] Univ Glasgow, Dept Stat, Glasgow, Lanark, Scotland
[3] Univ Glasgow, Dept Comp Sci, Vis & Graph Lab, 3D MATIC, Glasgow G12 8QQ, Lanark, Scotland
[4] Univ Birmingham, Sch Mfg & Mech Engn, Birmingham, W Midlands, England
[5] Canniesburn Hosp, Glasgow, Lanark, Scotland
关键词
cleft lip and palate; facial analysis; facial deformities; morphometrics; 3D imaging;
D O I
10.1597/02-067
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to assess the accuracy of a newly developed three-dimensional (3D) imaging system in recording facial morphology. Methods: Twenty-one infants with cleft lip each had a full-face alginate impression taken at the time of primary lip repair, and a stone cast was constructed from each impression. Five anthropometric points were marked on each cast. Each cast was digitized, and the 3D co-ordinates of the five points were obtained using a co-ordinate measuring machine (CMM, Ferranti) of documented accuracy (9.53 mum). Each cast was scanned in four positions using a computerized stereophotogrammetry (C3D) system. The five points were located on the 3D images, and their 3D co-ordinates were extracted by three operators. The co-ordinate systems produced by C3D were aligned, via translation and rotation, to match the CMM co-ordinate system using partial ordinary procrustes analysis. The displacements of the adjusted C3D co-ordinates from the reference co-ordinates were then measured. Three different types of errors were identified: operator, system, and registration errors. Results: Operator error was within 0.2 mm of the true co-ordinates of the landmarks. C3D was accurate within 0.4 mm. The average displacement of points over the 21 casts at four positions for the three operators was 0.79 mm (median 0.68). Conclusions: The presented 3D imaging system is reliable in recording facial deformity and could be utilized in recording cleft deformities and measuring the changes following surgery.
引用
收藏
页码:523 / 529
页数:7
相关论文
共 27 条
[1]  
Ayoub A F, 1996, Int J Adult Orthodon Orthognath Surg, V11, P225
[2]  
Ayoub A F, 1997, Int J Adult Orthodon Orthognath Surg, V12, P79
[3]   A vision-based three-dimensional capture system for maxillofacial assessment and surgical planning [J].
Ayoub, AF ;
Siebert, P ;
Moos, KF ;
Wray, D ;
Urquhart, C ;
Niblett, TB .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1998, 36 (05) :353-357
[4]  
AYOUB AF, 2001, 9 INT C CLEFT PAL RE, P283
[5]  
Bourne C.O., 2001, Clin Orthod Res, V4, P105, DOI 10.1034/j.1600-0544.2001.040207.x
[6]   Three-dimensional facial anthropometry using a laser surface scanner: Validation of the technique [J].
Bush, K ;
Antonyshyn, O .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (02) :226-235
[7]   EVALUATION AND PREDICTION OF THE FACIAL APPEARANCE AFTER SURGICAL-CORRECTION OF MANDIBULAR HYPERPLASIA [J].
CHEN, LH ;
IIZUKA, T .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (05) :322-326
[8]   3-DIMENSIONAL INPUT OF BODY-SURFACE DATA USING A LASER-LIGHT SCANNER [J].
CUTTING, CB ;
MCCARTHY, JG ;
KARRON, DB .
ANNALS OF PLASTIC SURGERY, 1988, 21 (01) :38-45
[9]  
DRYDEN IL, 1998, STAT SHAPE ANAL, P92
[10]  
FARKAS LG, 1993, CLEFT PALATE-CRAN J, V30, P1, DOI 10.1597/1545-1569(1993)030<0001:AAAFOT>2.3.CO