Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)

被引:89
作者
Preibisch, C
Pilatus, U
Bunke, R
Hoogenraad, F
Zanella, F
Lanfermann, H
机构
[1] Univ Frankfurt, Dept Neuroradiol, D-60528 Frankfurt, Germany
[2] Philips Med Syst, Hamburg, Germany
[3] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1016/S1053-8119(03)00080-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination. At constant echo times, SENSE-EPI was either used to shorten the single volume acquisition times (TRmin) at matrix size 128 x 100 (22 slices) from 3.9 s (no SENSE) to 2.0 s at R = 3, or to increase the matrix size to 192 x 153 (22 slices), resulting in TRmin = 5.3 s for R = 2 or TRmin = 3.4 s for R = 3. At the lower resolution, the bisection of echo train length (R = 2) substantially reduced distortions and blurring, while signal-to-noise and statistical power (measured by cluster size and maximum t value per unit time) were hardly reduced. At R = 3 the additional gain in speed and distortion reduction was quite small, while signal-to-noise and statistical power dropped significantly. With enhanced spatial resolution the time course signal-to-noise was better than expected from theory for purely thermal noise because of a reduced contribution of physiological noise, and statistical power almost reached that of the regular, low-resolution single-shot EPI, with a slight drop off toward R = 3. Thus, SENSE-EPI allows to substantially increase speed and spatial resolution in fMRI. At SENSE reduction factors up to R = 2, the potential drawbacks regarding signal-to-noise and statistical power are almost negligible. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 69 条
  • [1] [Anonymous], 1998, ECHO PLANAR IMAGING
  • [2] [Anonymous], 1998, Echo-Planar Imaging: Theory, Technique and Application, DOI DOI 10.1177/004057368303900411
  • [3] Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
  • [4] 2-G
  • [5] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [6] FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI
    BISWAL, B
    YETKIN, FZ
    HAUGHTON, VM
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 537 - 541
  • [7] Reduction of physiological fluctuations in fMRI using digital filters
    Biswal, B
    DeYoe, EA
    Hyde, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 107 - 113
  • [8] DYNAMIC MAPPING OF THE HUMAN VISUAL-CORTEX BY HIGH-SPEED MAGNETIC-RESONANCE-IMAGING
    BLAMIRE, AM
    OGAWA, S
    UGURBIL, K
    ROTHMAN, D
    MCCARTHY, G
    ELLERMANN, JM
    HYDER, F
    RATTNER, Z
    SHULMAN, RG
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (22) : 11069 - 11073
  • [9] Ghost artifact reduction for echo planar imaging using image phase correction
    Buonocore, MH
    Gao, LS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) : 89 - 100
  • [10] Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications
    Cordes, D
    Turski, PA
    Sorenson, JA
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (09) : 1055 - 1068