Further evidence of false negative screening for lupus anticoagulants

被引:18
作者
Moore, G. W. [1 ]
Henley, A. [1 ]
Greenwood, C. K. [1 ]
Rangarajan, S. [1 ]
机构
[1] St Thomas Hosp, Ctr Haemostasis & Thrombosis, Haemophilia Reference Ctr, London SE1 7EH, England
关键词
lupus anticoagulant; false negative; screening; mixing studies; confirmatory tests;
D O I
10.1016/j.thromres.2007.05.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Accurate and timely detection of lupus anticoagulants (LA) is of diagnostic and prognostic importance due to the association of persistent LA with thrombotic disease. Antibody heterogeneity and assay variability complicate LA detection and weak antibodies can go undetected. Methods: Screen and confirm assays on equal volume mixing studies were performed on known LA using dilute Russell's viper venom time (DRVVT), dilute activated partial thromboplastin time (DAPTT) and activated seven lupus anticoagulant (ASLA) assay. Two established calculations for phospholipid dependence were applied to ascertain whether any antibodies diluted to within screening test reference ranges maintained a significant difference between screen and confirm results sufficient to imply LA activity. We then performed confirmatory tests on neat plasma samples from patients with thrombotic disease whose screening tests were within reference ranges. Results: Forty nine of 155 DRVVT positive LA were conventionally positive in the mixing studies and 8 of the 106 negative mixing studies showed significant screen and confirm test discordance. This was the case for 21 of 56 negative DAPTT mixing studies and 2 of 39 negative ASLA mixing studies. Performance of confirm assays on the neat plasma samples with screen results within reference ranges revealed possible LA activity in 19 of 166 DRVVT results, 63 of 184 DAPTT results and 9 of 117 ASLA results. Conclusions: LA activity can be demonstrated by assessment of screen and confirm data irrespective of screening test elevation above a reference range. Other workers have demonstrated this phenomenon in APTT using different study designs and it may be that standard interpretation criteria warrant re-assessment. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 33 条
[1]  
Arnout J, 1999, THROMB HAEMOSTASIS, V81, P929
[2]  
Arnout J, 2001, THROMB HAEMOSTASIS, V86, P83
[3]   The antiphospholipid thrombosis syndromes: A common multidisciplinary medical problem [J].
Bick, RL .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 1997, 3 (04) :270-283
[4]   A rapid screen for lupus anticoagulant with good discrimination from oral anticoagulants, congenital factor deficiency and heparin, is provided by comparing a sensitive and an insensitive APTT reagent [J].
Brancaccio, V ;
Ames, PRJ ;
Glynn, J ;
Iannaccone, L ;
Mackie, IJ .
BLOOD COAGULATION & FIBRINOLYSIS, 1997, 8 (03) :155-160
[5]  
BRANDT JT, 1995, THROMB HAEMOSTASIS, V74, P1185
[6]   The use of frozen-thawed platelet-derived phospholipids as a confirmatory test for the diagnosis of lupus anticoagulants. Comparison with two commercial confirmatory system tests [J].
Cappucci, G ;
Grandone, E ;
Giuliani, N ;
Margaglione, M ;
Di Minno, G .
THROMBOSIS RESEARCH, 1999, 94 (06) :373-380
[7]  
CLYNE LP, 1993, ARCH PATHOL LAB MED, V117, P595
[8]   As compared to kaolin clotting time, silica clotting time is a specific and sensitive automated method for detecting lupus anticoagulant [J].
Dragoni, F ;
Minotti, C ;
Palumbo, G ;
Faillace, F ;
Redi, R ;
Bongarzoni, V ;
Avvisati, G .
THROMBOSIS RESEARCH, 2001, 101 (02) :45-51
[9]  
FORASTIERO RR, 1994, THROMB HAEMOSTASIS, V72, P728
[10]   The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant [J].
Gardiner, C ;
Mackie, IJ ;
Malia, RG ;
Jones, DW ;
Winter, M ;
Leeming, D ;
Taberner, DA ;
Machin, SJ ;
Greaves, M .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 111 (04) :1230-1235